COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT MODEL
COIL
CFM RANGE
(MIN.-MAX.)
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER
1
EER
TOTAL SENS.
14.5 SEER AC COIL ONLY RATINGS
TCGF18S41S3(E)
FC/MC/PC18 14.5,17.5 450-750 600 17.3 12.4 14.00 11.50
FC/MC/PC32 14.5 450-750 600 17.8 12.8 14.50 12.00
FC/MC/PC35 17.5,21.0 450-750 600 17.8 12.8 14.50 12.00
FC/MC/PC37 14.5 450-750 600 18.0 12.9 14.75 12.00
FC/MC/PC43 17.5,21.0 450-750 600 18.0 12.9 14.75 12.00
HD24 450-750 600 17.9 12.8 14.50 12.00
HD36 450-750 600 17.3 11.9 14.00 11.50
UC18 14.5,17.5 450-750 600 17.4 12.5 14.00 11.75
TCGF24S41S3(E)
FC/MC/PC32 14.5 500-900 700 24.4 17.2 14.50 12.30
FC/MC/PC35 17.5,21.0 500-900 800 25.0 17.6 14.50 12.35
FC/MC/PC37 14.5 500-900 800 25.4 17.9 14.50 12.35
FC/MC/PC43 17.5,21.0 500-900 800 25.2 18.0 14.70 12.50
FC/MC/PC48 21.0,24.5 500-900 800 25.6 18.3 14.80 12.65
HD36 500-900 800 24.8 17.0 14.00 12.00
HD48 500-900 800 25.6 17.9 14.50 12.35
TCGF30S41S3(E)
FC/MC/PC32 14.5 800-1200 1000 29.0 21.0 14.00 12.00
FC/MC/PC35 17.5,21.0 800-1200 1000 29.0 21.0 14.00 12.00
FC/MC/PC37 14.5 800-1200 1000 29.6 21.6 14.50 12.35
FC/MC/PC43 17.5,21.0 800-1200 1000 29.6 21.8 14.50 12.30
FC/MC/PC48 21.0,24.5 800-1200 1000 30.0 21.8 14.50 12.35
HD36 800-1200 1000 28.8 20.2 14.00 12.00
HD48 800-1200 1000 29.8 21.4 14.50 12.35
TCGF36S41S3(E)
FC/MC/PC37 14.5 1000-1400 1200 34.4 25.2 14.50 12.20
FC/MC/PC43 17.5,21.0 1000-1400 1200 34.2 25.0 14.50 12.30
FC/MC/PC48 21.0,24.5 1000-1400 1200 34.6 25.4 14.50 12.25
FC/MC/PC60 21.0,24.5 1000-1400 1200 34.0 25.4 14.25 12.00
FC/MC62 24.5 1000-1400 1200 34.4 25.8 14.50 12.25
FC64 24.5 1000-1400 1200 35.6 26.8 14.75 12.50
HD48 1000-1400 1200 34.6 25.0 14.50 12.20
UC60 21.0,24.5 1000-1400 1200 33.2 23.8 14.00 11.75
TCGF42S41S3(E)
FC/MC/PC43 17.5,21.0 1200-1600 1400 40.5 30.4 14.00 12.00
FC/MC/PC48 21.0,24.5 1200-1600 1400 40.5 30.4 14.50 12.00
FC/MC/PC60 21.0,24.5 1200-1600 1400 41.0 30.8 14.50 12.30
FC/MC62 24.5 1200-1600 1400 41.0 31.0 14.50 12.30
FC64 24.5 1200-1600 1400 41.5 32.0 14.75 12.25
HD48 1200-1600 1400 41.0 30.4 14.25 12.10
HD60 1200-1600 1400 41.5 31.2 14.50 12.30
TCGF48S41S4(E)
FC/MC/PC48 21.0,24.5 1400 - 1800 1600 44.5 32.8 14.25 11.75
FC/MC/PC60 21.0,24.5 1400 - 1800 1600 45.5 31.8 14.25 11.75
FC/MC62 24.5 1400 - 1800 1600 46.0 32.8 14.50 12.00
FC64 24.5 1400 - 1800 1600 46.5 33.8 14.75 12.25
HD60 1400 - 1800 1600 46.5 32.4 14.50 12.00
UC48 21.0,24.5 1400 - 1800 1600 44.5 32.8 14.25 11.75
UC60 21.0,24.5 1400 - 1800 1600 45.0 31.8 14.25 11.75
TCGF60S41S4(E)
FC/MC/PC60 21.0,24.5 1600 - 2000 1800 54.5 36.8 13.50 11.75
FC/MC62 24.5 1600 - 2000 1800 56.0 38.6 14.00 12.00
FC64 24.5 1600 - 2000 1800 57.0 40.5 14.25 12.25
HD60 1600 - 2000 1800 56.5 38.1 14.00 12.00
UC60 21.0,24.5 1600 - 2000 1800 55.0 37.4 13.75 11.75