EasyManua.ls Logo

York MX Series - Cooling Models with Electric Heat Wiring; Single-Stage Heat Pump Wiring

York MX Series
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
819682-UIM-A-0212
Johnson Controls Unitary Products 13
* Optional dehumidification humidistat switch contacts open on rise.
Notes:
1. “Y/Y2” Terminal on air handler control board must be connected for full CFM and applications requiring 60 second blower off delay for SEER enhancement.
2. Remove humidistat jumper on air handler control board.
3. For heat pump applications - set MODE jumper on air handler control board to the HP position.
4. To change quantity of heat during HP defrost cycle - reverse connections at W1 and W2 on air handler control board.
* Optional dehumidification humidistat switch contacts open on rise.
Notes:
1. “Y/Y2” Terminal on air handler control board must be connected for full CFM and applications requiring 60 second blower off delay for SEER enhancement.
2. Remove humidistat jumper on air handler control board.
3. For heat pump applications - set MODE jumper on air handler control board to the HP position.
4. To change quantity of heat during HP defrost cycle - reverse connections at W1 and W2 on air handler control board.
FIGURE 10:
Cooling Models with Electric Heat Wiring
FIGURE 11: Single-Stage Heat Pump Wiring

Related product manuals