EasyManua.ls Logo

York PC9C16N080UP11 User Manual

York PC9C16N080UP11
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TECHNICAL GUIDE
AFFINITY
MODELS: PC9*UP
GAS-FIRED
CONDENSING / HIGH EFFICIENCY
UPFLOW MODULATING FURNACES
WITH ECM MOTORS
NATURAL GAS
60 - 120 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
246813-YTG-D-0108
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
5-year limited parts warranty.
FEATURES
Modulating heating operation includes:
- Modulating gas valve
- Modulating inducer operation
Provides increased comfort level & very quiet unit opera-
tion
Compact, easy to install, ideal height 40" cabinet
Blower-off delay for cooling SEER improvement.
Easy to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement applica-
tion.
Integrated control module for reliable, economical opera-
tion.
May be installed as either two-pipe (direct vent) or single
pipe vent (using indoor combustion air)
Top intake & vent connection allows installation in narrow
locations.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
Induced combustion system with inshot main burners for
quiet, efficient operation.
No special vent termination kit required.
100% shut off main gas valve for extra safety.
ECM high efficiency direct drive motor with large, quiet
blower.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Secondary (condensing) heat exchanger of 29-4C high-
grade stainless steel.
Solid removable bottom panel allows easy application.
Easy access from front of unit for cleaning, maintenance or
service.
Protection from intake, exhaust or condensate blockage.
Insulated blower compartment for quiet operation.
Question and Answer IconNeed help?

Do you have a question about the York PC9C16N080UP11 and is the answer not in the manual?

York PC9C16N080UP11 Specifications

General IconGeneral
BrandYork
ModelPC9C16N080UP11
CategoryFurnace
Input BTU80, 000
AFUE96%
Blower Motor TypeVariable Speed
VentilationDirect Vent
Ignition TypeHot Surface Ignition
Warranty10 year
Heating Capacity80000 BTU

Summary

Product Overview and Features

Description

Details the Category IV, highly efficient, compact, condensing type furnaces for residential and commercial use.

Warranty Information

Outlines lifetime limited warranty on heat exchangers and 5-year limited parts warranty.

Key Features

Highlights modulating operation, compact design, self-diagnostics, and efficient ignition.

Dimensional Specifications

Cabinet Dimensions

Provides detailed cabinet dimensions (A, B, C, D) for various YORK Affinity furnace models.

Performance Data

Electrical and Performance Data

Details input/output MBH, blower size, AFUE, wire size, and operating weight for each model.

Thermostat Wiring Diagrams

AC 26A Configuration

Diagram showing thermostat connections for AC 26A with variable speed modulating furnace.

AC 26B Configuration

Diagram showing thermostat connections for AC 26B with variable speed modulating furnace.

AC 26C Configuration

Diagram showing thermostat connections for AC 26C with variable speed modulating furnace.

HP 28A Configuration

Diagram for HP 28A heat pump with variable speed modulating furnace and YORKGUARD VI control.

HP 28C Configuration

Diagram for HP 28C heat pump with variable speed modulating furnace and YORKGUARD VI control.

Air Flow Data

CFM Specifications

Provides airflow data (CFM) for various models under different speed and cooling/heat pump settings.

Installation and Accessories

Filter Performance

Details pressure drop values for different filter types and airflow ranges.

Clearances to Combustibles

Specifies required clearances for furnace installation near combustible materials.

Available Accessories

Lists optional accessories like LP conversion kits, vent terminations, and thermostats.

Related product manuals