EasyManua.ls Logo

York PC9C20N100UP11 - Thermostat Wiring Diagrams (AC 26 C); AC 26 C System Connections

York PC9C20N100UP11
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
246813-YTG-D-0108
6 Unitary Products Group
Thermostat Chart -
Optional Harness
AC 26C Two Stage Air Conditioner – Variable Speed Modulating Furnace
TWO STAGE
AIR
CONDITIONER
C
24 – Volt Common
R
24 – Volt Hot
Y1
First Stage Compressor
Y2
Second Stage
Compressor
C
24 – Volt Common
Y1
First Stage Compressor
L
Malfunction Light
Y2
Second Stage
Compressor
G
Fan
*PP32U71124
*PP32U72124
THERMOSTAT
R
24 – Volt Hot
W2
Second Stage Heat
DHM
Dehumidification
HM
Humidistat
Step 1 of Thermostat User
Configuration Menu must
be set to MLTISTG
E/W1
First Stage Heat
24VAC Humidifer
(Optional)
C
24 – Volt Common
R
24 – Volt Hot
Y1
Single Stage Compressor
VARIABLE SPEED
MODULATING
FURNACE CONTROL
G
Fan
VARIABLE SPEED
MODULATING
FURNACE
Y/Y2
Second or Full
Stage Compressor
HUM
Dehumidification-
Open on Humidity Rise
W
Modulating Heat
Part Numbers:
SAP = Legacy
171334 = 031-09153
1
1
Move HUMIDISTAT
jumper to “YES
if humidistat is to be used.
FL9C
FC9C
PC9
ID MODELS
Comfort Alert Interface
(two pin connector)
E2/P Switch must be in the
E2 position
Step 16 of Thermostat
Installer Table Menu
must be set to ON to use
Comfort Alert Features
Only applies to
*PP32U72124