14 Johnson Controls Unitary Products
1. Airflow tested with dry coil conditions, without air filters, at 230 volts
2. Applications above 0.8" w.c. external static pressure are not recommended.
3. Brushless DC high efficiency enhanced ECM blower motor used for all indoor blower assemblies.
4. Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases.
5. Minimal variations in airflow performance data results from using downflow duct applications. Data above may be used in those cases.
6. Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards.
60100
High Cool
A 2149 2114 2077 2030 1989
1948 1905 1859 1816 1768
B 2013 1977 1941 1898 1860
1816 1772 1726 1677 1630
C 1936 1900 1864 1822 1783
1739 1695 1649 1597 1551
D 1719 1685 1642 1600 1555
1508 1465 1418 1372 1327
Low Cool
A 1629 1591 1546 1502 1455
1409 1362 1315 1266 1220
B 1558 1516 1469 1423 1375
1329 1280 1232 1181 1135
C 1453 1406 1355 1305 1255
1207 1153 1100 1047 997
D 1410 1361 1307 1255 1204
1155 1100 1044 992 938
High Heat
A 1739 1705 1664 1620 1577
1530 1487 1441 1393 1348
B 1558 1516 1469 1423 1375
1329 1280 1232 1181 1135
C 1410 1361 1307 1255 1204
1155 1100 1044 992 938
D 1323 1270 1213 1156 1104
1052 993 933 880 821
Low Heat
A 1594 1553 1507 1462 1415
1369 1321 1274 1223 1178
B 1323 1270 1213 1156 1104
1052 993 933 880 821
C 1181 1118 1049 980 913
857 795 743 696 640
D 1025 950 868 788 713
654 591 505 458 415
60125
High Cool
A 2149 2114 2077 2030 1989
1948 1905 1859 1816 1768
B 2013 1977 1941 1898 1860
1816 1772 1726 1677 1630
C 1936 1900 1864 1822 1783
1739 1695 1649 1597 1551
D 1719 1685 1642 1600 1555
1508 1465 1418 1372 1327
Low Cool
A 1629 1591 1546 1502 1455
1409 1362 1315 1266 1220
B 1558 1516 1469 1423 1375
1329 1280 1232 1181 1135
C 1453 1406 1355 1305 1255
1207 1153 1100 1047 997
D 1410 1361 1307 1255 1204
1155 1100 1044 992 938
High Heat
A 2259 2221 2183 2142 2099
2060 2015 1975 1931 1882
B 2093 2059 2023 1977 1938
1896 1852 1805 1760 1712
C 1908 1872 1835 1792 1753
1709 1665 1619 1566 1522
D 1760 1726 1685 1641 1598
1552 1510 1463 1413 1370
Low Heat
A 2259 2221 2183 2142 2099
2060 2015 1975 1931 1882
B 1965 1929 1893 1851 1813
1769 1724 1678 1628 1580
C 1701 1666 1623 1580 1535
1488 1445 1397 1351 1305
D 1683 1648 1604 1560 1515
1468 1424 1377 1330 1284
NOTES:
Table 11: Airflow Performance - Side Duct Application (Continued)
Model Jumper Position
External Static Pressure (Inches WC)
0.1 0.2 0.3 0.4 0.5
0.6 0.7 0.8 0.9 1.0
SCFM SCFM SCFM SCFM SCFM
SCFM SCFM SCFM SCFM SCFM