EasyManua.ls Logo

York Predator ZT061 - Prior Nomenclature

York Predator ZT061
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5167821-YTG-J-0518
4 Johnson Controls Ducted Systems
Prior Nomenclature
Z T 061 N05 A 2 A ZZ 7 0 1 2 4 A
Product Category
Z = A/C, Single Pkg., R-410A
Product Generation
7 = Seventh Generation
037 = 3 Ton
Nominal Cooling Capacity
049 = 4 Ton
061 = 5 Ton
Product Identifier
T = 18 SEER Ultra High Eff. A/C
Voltage
2 = 208/230-3-60
4 = 460-3-60
5 = 575-3-60
Product Style
A = Style A
B = Style B
C = Style C
A = No Options Installed
Installation Options
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Option
s 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Options
SS Drain Pan
Configuration Options (not required for all units)
CPC Controller, DFS, APS
Honeywell Controller, DFS, APS
Novar Controller, DFS, APS
2" Pleated Filters, MERV 7
BAS Ready Unit with Economizer
York Commercial Comfort System (YCCS) Rtu Controller
Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned
Phase Monitor
Coil Guard
Dirty Filter Switch
Additional Options
American Flag
Technicoat Condenser Coil
Technicoat Evaporator Coil
3-5 Ton York
®
Model Number Nomenclature
For Units Produced Before 2-01-2016
ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be
located in digits 15-18.
Two Stage Natural Gas Heat Options
E03 = 3 KW (037)
E06 = 6 KW (037, 049, 061)
E08 = 9 KW (037, 049, 061)
E15 = 15 KW (037, 049, 061)
E20 = 20 KW (049, 061)
E23 = 24 KW (061)
N05 = 49 MBH Output Aluminized Steel,
Two Stage (037, 049)
N07 = 65 MBH Output Aluminized Steel,
Two Stage (037, 049, 061)
N09 = 97 MBH Output Aluminized Steel,
Two Stage (037, 049, 061)
N13 = 129 MBH Output Aluminized Steel,
Two Stage (061)
S05 = 49 MBH Output Stainless Steel,
Two Stage (037, 049)
S07 = 65 MBH Output Stainless Steel,
Two Stage (037, 049, 061)
S09 = 97 MBH Output Stainless Steel,
Two Stage (037, 049, 061)
S13 = 129 MBH Output Stainless Steel,
Two Stage (061)
Heat Type and Nominal Heat Capacity
C00 = Cooling Only. No heat installed
Electric Heat Options
York Commercial Comfort System (YCCS) Rtu Controller
4" Pleated Filters, MERV 13
E-Coat Condenser Coil
E-Coat Evaporator Coil
Shipping Bag
Airow
Simplicity®Smart Equipment w/Comm Card (BACnet, N2, Mod-Bus)
A = Std. Motor
D = Std. Motor/Motorized Damper (Downow Only)
H = Std Motor/Low Leak Econ/Barometric Relief (Downow
& Horizontal End Return Only)
J = Std Motor/Low Leak Econ/Power Exhaust (Downow
& Horizontal End Return Only)
N = Hi Static
R = Hi Static/Motorized Damper (Downow Only)
V = Hi Static Mtr/Low Leak Econ/Barometric Relief
(Downow & Horizontal End Return Only)
W = Hi Static Mtr/Low Leak Econ/Power Exhaust
(Downow & Horizontal End Return Only)
Fault Detection and Diagnostics (FDD)