8. Troubleshooting
8.1 Indoor Unit Error Display
Operation lamp
Timer lamp
Display
LED STATUS
1 time
X
E1
EEPROM parameter error
2 times
X
E2
Zero-crossing signal detection error
3 times
X
E3
Indoor fan speed has been out of control
5 times
X
E5
Indoor room temperature sensor T1 open circuit or
short circuit
6 times
X
E6
Evaporator coil temperature sensor T2 open circuit or
short circuit
7 times
X
E7
Condenser coil temperature sensor T3 open circuit or
short circuit
2 times
O
EC
Refrigerant Leakage Detection
9 times
X
E9
Indoor / outdoor units communication error
Olight Xoff ☆(flash