EasyManua.ls Logo

York S1-THSU32HP7 User Manual

York S1-THSU32HP7
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Owners Manual
Owners Manual
Digital Thermostat
LX Series
Digital Thermostat
LX Series
RESIDENTIAL
S1-THSU21P1
S1-THSU32P7
S1-THSU32HP7
Model
BACKLIT DISPLAY
and
and
Installation Instructions
Installation Instructions

Questions and Answers:

York S1-THSU32HP7 Specifications

General IconGeneral
BrandYork
ModelS1-THSU32HP7
CategoryThermostat
LanguageEnglish

Summary

Quick Start

Setting the Clock and Day

Instructions on how to set the clock and day on the thermostat, including tips for adjusting by the hour.

Selecting the Heat or Cool Mode

Explanation of how to select between Heating Only, Cooling Only, Auto-Changeover, and Off modes.

Selecting Your Desired Temperature

Guide on adjusting temperature setpoints in Auto, Heat, or Cool modes for optimal comfort.

Using the Fan Button

Instructions on how to operate the fan manually for continuous or on-demand airflow.

Viewing Temperature Sensors

How to display outdoor and remote sensor temperatures, including high/low values.

Indoor Humidity Sensor Viewing

How to view and adjust indoor humidity setpoints for better climate control.

Installation Instructions

Remove & Replace Old Thermostat

Step-by-step guide for safely removing an old thermostat and preparing for the new installation.

Wire Connections

Chart mapping old thermostat terminals to new ones and wiring diagrams for various systems.

Thermostat Backplate Details

Diagram and explanation of the thermostat backplate terminals and connections for installation.

Thermostat Jumper Explanation

Details on configuring the thermostat's functionality using jumpers for system type and operation.

Sample Wiring Diagrams

Illustrative wiring diagrams for conventional heating and cooling systems with various configurations.

Heat Pump Wiring Diagrams

Wiring diagrams for heat pump systems, including single/multi-stage cooling and heating configurations.

Dual Fuel & Humidification Wiring

Wiring diagrams for dual fuel heat pumps and systems with humidification/dehumidification and dry contact outputs.

Test Operation Guide

Guide for using the thermostat's diagnostic feature to test all equipment outputs and settings.

User Setup

Backlight Operation Modes

How to set and adjust the thermostat's backlight for visibility and power saving.

Backlight Brightness Level

Adjusting the brightness of the thermostat's backlight from off to seven levels.

Language Setting

How to change the display language for setup instructions (English, Spanish, French).

Scrolling Display Options

Options to customize how text scrolls on the thermostat display, including speed and format.

Display Icon Customization

How to remove or show icons on the thermostat display for a cleaner interface.

Vacation Mode Setup

Setting temporary energy-saving temperatures for periods when the home is unoccupied.

Emergency Heat Function

How to activate Emergency Heat mode for heat pump systems during critical heating demand.

Accessory Linking and Viewing

Linking and viewing wireless accessories, sensors, and other devices with the thermostat.

System Runtimes Overview

Monitoring equipment runtimes and programming service alerts for filters and UV lamps.

Service Filter Alerts

Configuring runtime and calendar alerts for filter replacement.

Energy Watch Runtime Tracking

Tracking heating, auxiliary heat, and cooling system runtime hours for performance monitoring.

UV Lamp Runtime Tracking

Monitoring UV lamp runtime and setting calendar alerts for replacement.

Humidifier Runtime Tracking

Tracking humidifier runtime and setting calendar alerts for service.

Time Period Programming

Setting up daily schedules with up to four programmable time periods for temperature control.

Daily Schedule Programming

Step-by-step guide to program morning, day, evening, and night periods and setpoints.

Installer Setup

Installer Setup Introduction

Overview of installer setup for configuring program modes and available system modes.

Program Mode Configuration

Setting the thermostat for 7-day, 1-day, 5/2-day, or non-programmable operation.

Available Modes Selection

Choosing between Auto-Changeover, Heat/Cool, Heat Only, or Cool Only modes for system operation.

Setpoint Limits Configuration

Restricting heat and cool setpoints to preset levels for energy management.

Cycles Per Hour Setting

Limiting the number of HVAC cycles per hour to improve efficiency and lifespan.

Compressor Minimum Off Time

Setting a minimum off-time for the compressor to prevent short cycling and damage.

Minimum Setpoint Difference

Defining the minimum gap between heat and cool setpoints in Auto mode.

Compressor Stage Configuration

Setting the number of compressor stages for heat pump applications.

Deadband Settings Explained

Configuring temperature differences (deadbands) and time delays between heating/cooling stages.

Fan Programming Options

Setting up automatic fan operation schedules for circulation and air quality.

Fan Off Delay Setting

Adjusting the fan's off-delay time to improve cooling or electric heat efficiency.

Comfort Recovery Setup

Enabling the thermostat to reach setpoints precisely at the scheduled time.

Humidity and Dehumidification Setup

Configuring humidity control, including setpoints, fan operation, and modes.

Heat Pump Outdoor Temp Lockout

Preventing heat pump operation below a specific outdoor temperature for efficiency.

Auxiliary Heat Lockout Setup

Locking out auxiliary heat above a set outdoor temperature to optimize heat pump usage.

Dual Fuel System Setup

Configuring dual fuel systems for optimal switching between heat pump and fossil fuel sources.

Dual Fuel System Settings

Fine-tuning dual fuel operation with safety timers, balance points, and changeover delays.

Temperature Source Control

Selecting the sensor source (thermostat, remote, or average) for room temperature readings.

Temperature Units Selection

Choosing to display temperature in Fahrenheit or Celsius.

Fault Type Configuration

Setting how fault signals are interpreted and displayed for system diagnostics.

Auxiliary Output Configuration

Setting up and controlling a programmable auxiliary output for various functions.

Auxiliary Output Time Programming

Programming the auxiliary output to turn on/off based on time of day, day of week, and specific events.

Auxiliary Output Temp Programming

Configuring the auxiliary output to trigger based on temperature sources and setpoints.

Free Cooling Setup

Enabling free cooling to use outside air for cooling, reducing reliance on the air conditioner.

Venting Operation

Setting up the venting feature to exhaust indoor air to the outside during a cooling call.

Dry Contact Operation

Configuring dry contact polarity and use for external device integration or alerts.

Factory Default Reset

Instructions on how to reset all stored settings back to the thermostat's factory defaults.

Keypad Lockout

How to enable or disable keypad lockout to prevent unauthorized thermostat access.

Technician Setup

Technician Setup Overview

Guide for qualified technicians to perform diagnostics, testing, and calibration.

Warranty

Warranty Information

Details of the product's limited warranty, terms, conditions, and exclusions.

Related product manuals