Do you have a question about the York SUNLINE 2000 2000 and is the answer not in the manual?
Overview of YORK Sunline 2000 Heat Pumps, convertible single package units.
Highlights of the heat pump's design and performance capabilities.
Details on defrost circuits and thermostat compatibility.
Information on convertible airflow and duct configurations.
Economizers and belt-drive blowers available from the factory.
Accessories for easy installation like motorized dampers and electric heaters.
Models operate over a wide range of design conditions with multi-speed motors.
Permanent base rails for solid foundation, forklift access, and rigging.
Components protecting the compressor and system from various conditions.
Ease of making electrical utility connections and disconnect switch mounting.
Details on mate-n-lock connectors and control box location.
Standard 1" throwaway filters and compatibility with 1" or 2" filters.
Cooling and heating capacity ratings based on ARI standards.
Sound power levels in decibels for various frequencies.
Dimensions and specifications for basic unit components.
Detailed cooling capacity data for the 3-ton model at various conditions.
Detailed cooling capacity data for the 4-ton model at various conditions.
Detailed cooling capacity data for the 5-ton model at various conditions.
Heating capacity data for different models at various outdoor temperatures.
Supply air blower performance for BCH036 and 048 models with belt-drive.
Supply air blower performance for BCH060 models with belt-drive.
Supply air blower performance for BCH036, 048, 060 models with direct-drive.
Specifications for belt-drive motors, pulleys, and frame sizes.
External static pressure drop values for duct connections and accessories.
Minimum supply air CFM requirements for various heater sizes.
Wiring diagrams for thermostats, control circuits, and power supply.
Electrical specifications for basic and heat pump direct-drive units.
Electrical specifications for basic and heat pump belt-drive units.
Overall dimensions of the BCH unit, including base rails and duct openings.
Knockout hole sizes and their usage for wiring and entry.
Minimum clearances for installation around the unit.
Instructions for removing and installing duct covers for different applications.
Diagrams showing dimensions for units with economizer or damper rainhoods.
Dimensions for the 14" and 8" high roof curb assembly.
Weight distribution and center of gravity for unit components.
Details on single and dual input electronic enthalpy economizers.
List and description of field-installed accessories.
Illustrations of typical roof jack, roof curb, and slab on ground installations.
Overview of unit design, assembly, testing, and certifications.
Details on cabinet materials, insulation, panels, base rails, and filters.
Specifications for the direct-drive or belt-drive supply fan.
Details on the direct-driven propeller type outdoor fan.
Specifications for compressors, coils, and safety components.
Low-voltage control circuit and safety device lock-out.
Operating capabilities at high outdoor temperatures and low ambient cooling.
Warranty periods for compressor, electric heat elements, and parts.
Details on electronic enthalpy economizers for outdoor air control.
Available accessories like roof curbs, coil guards, and dampers.
Information on thermostat compatibility and electric heat options.