EasyManua.ls Logo

York Sunline 2000 - Table of Contents; Nomenclature

York Sunline 2000
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General ................................................................................ 1
Inspection............................................................................. 1
Reference............................................................................. 1
Approvals ............................................................................. 1
Nomenclature....................................................................... 2
INSTALLATION
Limitations............................................................................ 3
Location ............................................................................... 3
Condensate Drainage Precaution ....................................... 3
Rigging and Handling .......................................................... 3
Clearances........................................................................... 3
Ductwork .............................................................................. 3
Filters ................................................................................... 4
Condensate Drain................................................................ 4
Service Access .................................................................... 4
Blower Speed Selection....................................................... 4
Disconnect Switch Bracket For Optional Belt-Drive ............ 4
Compressors........................................................................ 4
Thermostat........................................................................... 4
Power and Control Wiring .................................................... 4
Electric Heaters ................................................................... 5
Optional Economizer Rain Hood ......................................... 6
OPERATION
Cooling System.................................................................. 12
Preliminary Operation Cooling........................................... 12
Cooling Sequence of Operation......................................... 12
Heating Sequence of Operation ........................................ 12
Defrost Sequence of Operation ......................................... 12
Lockout Control.................................................................. 13
Checking Supply Air CFM.................................................. 13
Secure Owner’s Approval .................................................. 14
MAINTENANCE
Normal Maintenance ......................................................... 14
TABLES
No. Description Page
1 Unit Application Data.................................. 3
2 Air Flow Limitations..................................... 5
3 Physical Data.............................................. 7
4 Supply Air Perf.
3 & 4 Ton w/Belt-Drive Blower
.. 9
5 Supply Air Perf.
5 Ton w/Belt-Drive Blower
........ 10
6 Supply Air Perf.
w/Direct-Drive Blower.......... 10
7 Static Resistances ...................................... 10
8 Motor and Drive Data - Belt-Drive Blower .. 11
9 Electrical Data w/Direct-Drive Blower......... 11
10 Electrical Data w/Belt-Drive Blower............ 11
11 Belt-Drive Supply Air Motor Pulley Adj.
......
13
FIGURES
No. Description Page
1 Center of Gravity......................................... 3
2 Recommended Drain Piping....................... 4
3 Typical Field Wiring..................................... 5
4 Economizer Rain Hood Assembly.............. 6
5 Adjusting Enthalpy Setpoint........................ 7
6 Dimensions and Clearances....................... 8
7 Defrost Initiation Times............................... 12
8 Ambient Modified Time/Temp. Control........ 12
9 Hole Loc. for Press. Drop Readings ........... 13
10 Press. Drop versus Supply Air CFM........... 13
TABLE OF CONTENTS
B 3 C H A
PRODUCT NOMENCLATURE
PRODUCT GENERATION
3 = Third Generation
4 = Fourth Generation
5 = Fifth Generation
PRODUCT CATEGORY
B = Single Package Heat Pump
(Air Cooled)
PRODUCT IDENTIFIER
CH = Heat Pump
VOLTAGE CODE
06 = 208/230-1-60
25 = 208/230-3-60
46 = 460-3-60
58 = 575-3-60
036 = 3 Ton
048 = 4 Ton
060 = 5 Ton
30 6 2 5
FACTORY INSTALLED HEAT
A = No Supplemental Heat
NOMINAL COOLING CAPACITY
511.06-N5Y