TECHNICAL GUIDE
SPLIT-SYSTEM
A
IR CONDITIONERS
13 SEER – R-410A
MODELS:
TCGD18 THRU 60
(1.5 THRU 5 NOMINAL TONS, 1 PHASE)
Due to continuous product improvement, specifications
are subject to change without notice.
V
isit us on the web at www.york.com
A
dditional rating information can be found at
w
ww.ahridirectory.org
LISTED
ISO 9001
Certified Quality
Management System
359315-YTG-B-0408
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The 13 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be cus-
tom-matched with one of UPG’s complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are available, if required. Add-on coils are available for use
with upflow, downflow, or horizontal furnaces and air han-
dlers.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
5-year limited compressor warranty.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed
of aluminum microchannel tubing and enhanced aluminum
fins for increased efficiency and corrosion protection.
PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure, temperature, and
externally by a factory installed high pressure switch. This
is accomplished by the simultaneous operation of high
pressure relief valve and a temperature sensor which pro-
tects the compressor if undesirable operating conditions
occur. A liquid line filter-drier further protects the compres-
sor.
DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimen-
sion means less space is required on the ground or roof.
TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, and a single panel covering the electrical con-
trols make for easy servicing of the unit.
SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
Question and Answer IconNeed help?

Do you have a question about the York TCGD18 THRU 60 and is the answer not in the manual?

York TCGD18 THRU 60 Specifications

General IconGeneral
BrandYork
ModelTCGD18 THRU 60
CategoryAir Conditioner
LanguageEnglish

Summary

Technical Guide Overview

Product Description

Overview of the 13 SEER Series condensing unit and its features.

Product Warranty Information

Details on the limited parts and compressor warranty for single phase units.

Key Product Features Summary

Highlights features like protected compressor, durable finish, and ease of service.

Physical and Electrical Specifications

Unit Dimensions and Connection Data

Physical dimensions and refrigerant connection sizes for each model.

R-410A Charge and Orifice Data

Indoor Coil Matching and Refrigerant Charge

Required R-410A charge and orifice size for matched indoor coil configurations.

R-410A Data Table Footnotes

Explanations for TXV kits, orifices, and coil compatibility notes.

R-410A Charge and Orifice Procedures

Refrigerant Charge Calculation Procedures

Steps for verifying TXV/orifice and calculating additional refrigerant charge.

Important Model Installation Notes

Notes on start kits for TXV matches and models with factory-installed kits.

Air Handler TXV Conversion Warning

Warning to change R-22 TXV to R-410A TXV to prevent system damage.

Cooling Capacity with Air Handler Coils

13 SEER AC with MA Series Air Handler Data

Cooling capacity data for 13 SEER AC units with MA series air handlers.

13 SEER AC with MV Variable Speed Handler Data

Cooling capacity data for 13 SEER AC units with MV variable speed air handlers.

13 SEER AC with AV/SV/F*FV Variable Speed Handler Data

Cooling capacity data for 13 SEER AC units with AV/SV/F*FV air handlers.

Cooling Capacity - Air Handler Coils (Continued)

13 SEER AC with AHP/SHP/F*FP Handler Data

Cooling capacity data for 13 SEER AC units with AHP/SHP/F*FP air handlers.

Cooling Capacity Calculation Notes

Notes on how indoor fan heat is included in capacity calculations.

Cooling Capacity with Furnaces

Furnace and Coil Matching for Cooling

Cooling capacity data when matched with various furnace types and CFM ranges.

Furnace Matching Specific Notes

Notes on blower time delay requirements and furnace selection.

Cooling Capacity with Variable Speed Furnaces

13 SEER AC with Variable Speed Furnace Data

Cooling capacity data for 13 SEER AC units with variable speed furnaces.

Variable Speed Furnace Cooling Data (Continued)

Variable Speed Furnace Installation Notes

Notes on MC coils and variable speed furnace blower-on delay.

Accessories and Installation Information

Optional Accessories for Units

Details on hard start kits, room thermostats, and off-cycle timers.

Sound Power Ratings

Sound power levels (dBA) rated in accordance with ARI 270-95 standards.

Typical Outdoor Unit Installation

Diagrams and notes for typical outdoor unit installation clearances and wiring.

Field Wiring Diagrams

Wiring diagrams for power, control, and factory wiring connections.

Cooling Performance Data: Page 11 Notes

Performance Data Adjustment Multipliers

Factors for adjusting performance based on different indoor coil matches.

Cooling Performance Data: Page 12 Notes

Capacity Calculation Notes for Performance Tables

Notes on how indoor fan heat is included in capacity calculations.

Cooling Performance Data: Page 13 Notes

Performance Data Adjustment Factors

Factors for adjusting cooling capacity based on different indoor coil selections.

Cooling Performance Data: Page 14 Notes

Cooling Capacity Adjustment Multipliers

Factors for adjusting cooling capacity based on different indoor coil selections.

Cooling Performance Data: Page 15 Notes

Cooling Capacity Factors

Factors for adjusting cooling capacity based on different indoor coil selections.

Cooling Performance Data: Page 16 Notes

Performance Data Multipliers

Factors for adjusting cooling capacity based on different indoor coil selections.

Cooling Performance Data: Page 17 Notes

Capacity Adjustment Factors

Factors for adjusting cooling capacity based on different indoor coil selections.

Related product manuals