556454-YTG-B-0410
Johnson Controls Unitary Products 3
System Charge for Various Matched Systems
Outdoor Unit TCHD18S41S3 TCHD24S41S3 TCHD30S41S3 TCHD36S41S3 TCHD48S41S3 TCHD60S41S3
Required Orifice or TXV
1
1TVM4F1 1TVM4F1 1TVM4G1 1TVM4G1 1TVM4J1 1TVM4K1
Factory Charge, lbs-oz 2 - 14 3 - 5 4 - 0 4 - 8 5 - 5 5 - 6
Indoor Coil
2,3
Additional Charge, oz
AHP24 –2––––
AHP36 – 16 12
AHP/SHP60 – 11
AHX18 0 0
AHX24 10 10
AHX30 13 14 10
AHX36 20 16 12
AHX42 27 22
AHX48 26 22 11
AHX60 27 16 13
AV24 22––––
AV36 20 20 16 12
AV/SV48 – 22 11
AV/SV60 ––––118
F*FP030 – 2 0
F*FP036 – 8 4
F*FP040 – 10 7
F*FP042 – 7
F*FP048 – 16 11
F*FP060 – 16
F*FV060 – 8 11 8
F6FP018 0–––––
F6FP024 33––––
F6FP030 14 15 10
F6FP036 –15107
F6FP042 20 16
F6FP048 10 7 11
F6FP060 271613
FC/MC/PC18 0–––––
FC/MC/PC24 00––––
FC/MC/PC30 442–––
FC/MC/PC32 13 14 10 6
FC/MC/PC35 13 14 0 6
FC/MC/PC36 6630––
FC/MC/PC37 20 21 16 12
FC/MC/PC42 –931––
FC/MC/PC43 –20160
FC/MC/PC48 322722 0
FC/MC/PC60 ––––10
FC/MC62 ––––160
HC18 00––––
HC30 10 10 7
HC36 13 14 10 6
HC42 211612
HC60 –––70–
HD24 22 17
HD36 28 20 14 11
HD48 –3324–
HD60 ––––3022
For notes see Page 4.