Johnson Controls Unitary Products 835964-UIM-A-0112
R-410A
OUTDOOR SPLIT-SYSTEM
AIR CONDITIONING
MODELS: 13 & 14.5 SEER -
TCG(D,F)/GCGD/TCJ(D,F)/YCJ(D,F) SERIES
1.5 TO 5 TONS – 1 & 3 PHASE
INSTALLATION MANUAL
®
LIST OF SECTIONS
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ‘1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
UNIT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
ORIFICE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
TXV INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
EVACUATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SYSTEM CHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
INSTRUCTING THE OWNER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
LIST OF FIGURES
Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation of Vapor Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Underground Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Heat Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Orifice Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Outdoor Unit Control Box (Single Phase) . . . . . . . . . . . . . . . . . . . . . .7
Outdoor Unit Control Box (Three Phase) . . . . . . . . . . . . . . . . . . . . . . .7
Typical Field Wiring (Air Handler / Electrical Heat) (Single-Phase) . . .8
Typical Field Wiring (Air Handler / Electrical Heat) (Three-Phase) . . . 8
Thermostat Chart - Single Stage AC with PSC Air Handler . . . . . . . . 9
Thermostat Chart - Single Stage AC with PSC Air Handler . . . . . . . 10
Thermostat Chart - Single Stage AC with PSC Furnace . . . . . . . . . 11
Thermostat Chart - Single Stage AC with PSC Furnace . . . . . . . . . 12
Wiring Diagram - Single Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Wiring Diagram - Three Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
LIST OF TABLES
Application Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 R-410A Saturation Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SECTION I: GENERAL
The outdoor units are designed to be connected to a matching indoor
coil with sweat connect lines. Sweat connect units are factory charged
with refrigerant for a matching indoor coil plus 15 feet of field-supplied
lines.
The refrigerant charge may need to be changed for some indoor-out-
door unit combinations, elevation differences or total line lengths. Refer
to Application Data covering “General Piping Recommendations and
Refrigerant Line Length” (Part Number 247077).
SECTION II: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury
.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury
.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury
. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
INSPECTION
As soon as a unit is received, it should be inspected for possible dam-
age during transit. If damage is evident, the extent of the damage
should be noted on the carrier’s delivery receipt. A separate request for
inspection by the carrier’s agent should be made in writing. See Local
Distributor for more information.
Requirements For Installing/Servicing R-410A Equipment
Gauge sets, hoses, refrigerant containers, and recovery system
must be designed to handle the POE type oils, and the higher
pressures of R-410A.
Manifold sets should be high side and low side with low side
retard.
All hoses must have a 700 psig service pressure rating.
Leak detectors should be designed to detect HFC refrigerant.
Recovery equipment (including refrigerant recovery containers)
must be specifically designed to handle R-410A.
Do not use an R-22 TXV.
A liquid-line filter drier is required on every unit.
This product must be installed in strict compliance with the
enclosed installation instructions and any applicable local, state,
and national codes including, but not limited to building, electrical,
and mechanical codes.
R-410A systems operate at higher pressures than R-22 systems.
Do not use R-22 service equipment or components on R-410A
equipment. Service equipment
Must Be Rated for R-410A.
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer or service agency.
Question and Answer IconNeed help?

Do you have a question about the York 13 Seer-TCGD and is the answer not in the manual?

York 13 Seer-TCGD Specifications

General IconGeneral
BrandYork
Model13 Seer-TCGD
CategoryAir Conditioner
LanguageEnglish

Summary

General Information

Safety Precautions and Requirements

Unit Inspection

Procedures for inspecting the unit for potential transit damage upon receipt.

R-410 A System Equipment

Specific requirements for R-410A systems, including tools and service practices.

Unit Installation Procedures

Installation Limitations

Key operational and installation limitations for the unit, including temperature and line length.

Add-On Replacement Retrofit

Procedures for replacing older R-22 systems with R-410A units.

Selecting the Installation Location

Guidance on selecting a suitable and safe location for the outdoor unit.

Ground and Roof Installation

Guidelines for installing the unit on the ground or on a roof structure.

Liquid Line Filter-Drier

Information about the liquid line filter-drier and its proper replacement.

Refrigerant Line Brazing

Safety precautions and procedures for brazing refrigerant lines and service valves.

Orifice and TXV Installation

Orifice Installation

Instructions for installing the orifice distributor assembly.

TXV Installation

Instructions for installing the Thermal Expansion Valve (TXV).

System Evacuation and Charge

System Evacuation

Procedures for evacuating the system to remove air and moisture.

System Charge Methods

Methods for determining and charging the system with the correct refrigerant amount.

Superheat Charging (Piston)

Superheat method for charging systems with piston distributors.

Subcooling Charging (TXV)

Subcooling method for charging systems with TXVs.

Electrical Connections

General Information and Grounding

General guidelines and grounding requirements for electrical connections.

Power Wiring Connections

Steps for connecting the main power wiring to the unit.

Control Wiring Connections

Steps for connecting the low-voltage control wiring.

Owner Instruction and Maintenance

Instructing the Owner

Guidance for installers on instructing the end-user on operation and maintenance.

Routine Maintenance

Routine maintenance tasks for the outdoor unit and system components.

Wiring Diagrams

Single Phase Wiring Diagram

Detailed wiring diagram for single-phase unit configurations.

Three Phase Wiring Diagram

Detailed wiring diagram for three-phase unit configurations.

Related product manuals