EasyManua.ls Logo

York VSD 424 User Manual

York VSD 424
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
035-27337-100
Form Number: 160.00-O4 (820)
Supersedes: 160.00-O4 (220)
Operation Manual
Issue Date: 2020-08-19
Liquid-Cooled OptiSpeed Compressor
Speed Drive
Models VSD 270, 292, 351, 385, 419, 424, 503, 608, 658, 704,
790, 868, 882, 917, 948, and 1055. Models LVD 270, 292, 351,
385, 419, 424, 503, 608, 658, 704, and 900.
Question and Answer IconNeed help?

Do you have a question about the York VSD 424 and is the answer not in the manual?

York VSD 424 Specifications

General IconGeneral
BrandYork
ModelVSD 424
CategoryInverter
LanguageEnglish

Summary

General Safety Guidelines

Safety Symbols

Symbols used to alert readers to specific situations.

Document Information

Document Changeability

Information is subject to change; users must verify applicability.

Revision Notes

Details revisions made to the document.

Associated Literature

Lists related manuals and their form numbers for reference.

Maintenance Strategies

Conditioned Based Maintenance

Data-driven maintenance program for optimal operation and lifecycle assurance.

VSD Model Nomenclature and Parts

VSD Model Nomenclature

Explains the nomenclature and part number breakdown for VSD models.

VSD Part Numbers and Descriptions

Lists VSD part numbers and their corresponding descriptions.

LVD Model Nomenclature and Parts

LVD Model Nomenclature

Explains the nomenclature and part number breakdown for LVD models.

LVD Part Numbers and Descriptions

OptiSpeed LVD Part Numbers

Lists OptiSpeed LVD part numbers and their descriptions.

System Components Overview

OptiSpeed/Harmonic Filter Components

Overview of OptiSpeed drive and harmonic filter components and operation.

Drive System Details

Harmonic Filter Option Details

Details the optional harmonic filter, its purpose, and components.

Model and Design Variations

G vs. W Design Differences

Compares G and W designs, focusing on cooling system variations.

VSD vs. LVD Model Differences

Compares VSD and LVD drives regarding harmonic filter integration.

Control System Architecture

OSCD Control System Overview

Overview of OSCD control system connection to Microcomputer or OptiView Control Center.

Control Center History

Control Center Before 2005

Details Microboard and ACC board functions in older control systems.

Control Center From 2005

Describes control system changes including new components and ports.

Control Boards and Adaptive Features

Logic Control Boards

Explains interconnection and function of OSCD and Harmonic Filter logic boards.

VSD Keypad Functions

Refers to keypad functions and display changes for VSD models.

VSD Adaptive Capacity Control

Describes YORK OSCD's adaptive speed reduction and surge avoidance.

Adaptive Capacity Control Operations

ACC Setpoint Requirements

Conditions for speed reduction based on leaving chilled liquid temperature.

ACC Stability Requirements

Conditions for speed reduction requiring stable temperature.

ACC Full Open Vane Operation

Describes operation when vanes are fully open and load increases.

ACC Effects of Surge

Explains surge detection and storage of surge points.

Adaptive Capacity Control Troubleshooting

Drive Not Reducing Speed Causes

Discusses reasons for speed reduction failure, including instability.

Stability Limit Adjustment

Adjustment for temperature instability; consult YORK Service.

Surge Margin Adjustment

Increases drive speed for surge points; rarely used.

System Architecture Diagrams

OptiSpeed System Architecture

Illustrates the VSD 351 system architecture without harmonic filter.

Printed Circuit Boards

VSD Logic Board

Image and location of the VSD logic board on the panel door.

SCR Trigger Board

Image of the SCR trigger board.

Additional Printed Circuit Boards

Harmonic Filter Logic Board

Image of the optional harmonic filter logic board on the panel door.

Gate Driver and Power Module

Image of the gate driver board and power module.

Safety Shutdowns

Safety Shutdown General Information

Explains the organization and event sequence of safety shutdowns.

Safety Shutdown Messages

VSD Safety Shutdown Messages

Details VSD shutdown messages, causes, and reset procedures.

Cycling Shutdowns

Cycling Shutdown General Information

Explains the organization and event sequence of cycling shutdowns.

VSD Cycling Shutdown Messages

Details VSD cycling shutdown messages, causes, and procedures.

Warning Messages

Warning Message General Information

Indicates affected OSCD/filter operation, but functionality remains.

Harmonic Filter Warning Messages

Details harmonic filter warning messages and their implications.

VSD Frequently Asked Questions

Common VSD FAQs

Answers common questions about OSCD operation, such as input amps and anti-recycle.

Unit Conversion

SI Metric Conversion Factors

Provides conversion factors for English to SI units for various measurements.

Related product manuals