INSTALLATION, OPERATION & MAINTENANCE
AIR-COOLED SCREW LIQUID CHILLERS
Supersedes: 201.18-NM1 (1298)
Form 201.18-NM1 (102)
YCAS AIR-COOLED SCREW LIQUID CHILLERS
YCAS0130 through YCAS0230
YCAS 2 SYSTEM EPROM 031-01798-001 (STANDARD, BRINE & METRIC MODELS COMBINED)
28971AR

Table of Contents

Questions and Answers

  • J
    Jennifer ThomasAug 6, 2025
    How to troubleshoot a York YCAS0160 Chiller with no display on the panel and that won't start?
    • C
      Carolyn EstradaAug 6, 2025
      If there is no display on the control panel and the York Chiller won't start, here's what you can check: * Ensure the main power supply to the control system is switched on. * Verify that the emergency stop switch on the control panel and any remote emergency stop devices are in the ON position. * Inspect the mains supply in case of an undervoltage relay trip. * Check the emergency stop switch fuses, wiring from - T2 to powerboard and fuse if there's no supply to - T2 or no 24VAC supply to the powerboard. * If there's no +12V output from the powerboard, consider replacing the powerboard or reducing excessive load on the board.
  • T
    Tara BrownAug 9, 2025
    What to do if my York YCAS0160 Chiller displays a HIGH AMBIENT TEMP fault?
    • W
      wwilliamsAug 9, 2025
      If your York Chiller displays a 'HIGH AMBIENT TEMP' fault, it means the ambient air temperature is exceeding the programmed operating limit. Use the 'ambient temp.' key to check the temperature reading. If the reading is accurate, the message should disappear once the ambient temperature drops below the limit. Also, verify that the programmed settings are correct for the unit's options. Check that the fan is operating correctly and the rotation is correct. Check for airflow recirculation. Finally, check the sensor calibration, location, and wiring to ensure accurate temperature measurement.
  • K
    Kristin GreeneAug 14, 2025
    How do I fix a HIGH OIL TEMP error on my York Chiller?
    • J
      joshuanicholsonAug 14, 2025
      If the York Chiller displays a 'HIGH OIL TEMP' message, it could be due to poor airflow through the condenser coils. Check for any obstructions blocking the intake faces of the air coils. Also, verify the accuracy of the temperature reading by checking the sensor calibration, location, and wiring.
  • J
    jhughesAug 18, 2025
    Why does my York YCAS0160 display 'NO RUN PERM'?
    • D
      Donald KirkAug 18, 2025
      If the York Chiller displays 'NO RUN PERM', it indicates a 'No run permissive' status. This can happen if there's no liquid flow through the cooler. Ensure that liquid pumps are running, valves are correctly set, and flow is established. Also, check that the flow switch is functional and correctly installed per the manufacturer's instructions, as the pump starter might be wired to and controlled by the unit on some systems.
  • V
    Veronica GordonAug 22, 2025
    What causes a LOW WATER TEMP fault on a York YCAS0160 Chiller?
    • D
      davisbethanyAug 23, 2025
      If the York Chiller displays a 'LOW WATER TEMP' fault, it could be due to several reasons. The leaving liquid temperature might be dropping below the programmed low limit faster than the unit can unload. Check for any restrictions in the liquid flow line and ensure stable liquid flow. Also, verify the unit is unloading correctly by checking the supply to the unloader valve solenoid and confirming the compressor unloads correctly. Finally, ensure the temperature readings are accurate by checking the sensor calibration, location, and wiring.
  • N
    Nicole BurgessAug 27, 2025
    What does LOW AMBIENT TEMP mean on my York YCAS0160 Chiller?
    • T
      Thomas FergusonAug 27, 2025
      If your York Chiller displays a 'LOW AMBIENT TEMP' fault, it means the ambient air temperature is below the programmed operating limit. Use the 'ambient temp.' key to display the temperature and confirm its accuracy. The warning should clear once the ambient temperature rises above the limit. Also, ensure the programmed settings are correct for the unit's options, and check the sensor calibration, location, and wiring.
  • J
    Jennifer EvansAug 31, 2025
    What causes VAC UNDERVOLTAGE fault on a York YCAS0160?
    • J
      John BoyleAug 31, 2025
      If the York Chiller displays 'VAC UNDERVOLTAGE', it indicates a problem with the mains supply voltage. Check that the mains supply is stable and within allowable limits. Also, check for any voltage dips when the compressor starts.

Summary

GENERAL CHILLER INFORMATION & SAFETY

SAFETY

Outlines safety standards and codes the YCAS chillers comply with.

EMERGENCY SHUTDOWN

Describes how to perform an emergency shutdown using stop switches and circuit breakers.

PRODUCT DESCRIPTION

Motor Current Protection

Explains how the microprocessor protects the motor from high and low current conditions.

INSTALLATION

ELECTRICAL CONNECTION

Provides crucial recommendations for safe and satisfactory electrical connection to prevent harm or damage.

COMMISSIONING

FIRST TIME START-UP

Provides a step-by-step guide for the initial start-up of the chiller unit.

CHECKING SUBCOOLING AND SUPERHEAT

Provides procedures for checking subcooling and superheat levels for system optimization.

OPERATION

START-UP

Guides on checking power supplies, valves, and system switches before starting the unit.

TECHNICAL DATA

OPERATING LIMITATIONS - ENGLISH UNITS

Specifies the operating limits for chilled liquid temperature, water side pressure, and refrigerant side pressure.

ELECTRICAL DATA

ELECTRICAL NOTES

Provides important notes and legends related to electrical data tables and wiring.

SYSTEM STARTUP CHECKLIST

Panel Checks

Guides on checks to be performed on the control panel after applying power.

INITIAL START-UP

Details the steps for placing the chiller into operation after programming and checks are complete.

STATUS KEY: GENERAL STATUS MESSAGES & FAULT WARNINGS

Low Motor Current Cutout; Motor Protector (Hi Motor Winding Temp Cutout); Mechanical High Pressure Cutout;External Motor Overload

Covers motor protection features including low current, high winding temp, high pressure, and external overload.

SETPOINTS KEYS & CHILLED LIQUID CONTROL

Compressor Starting & Loading Sequence

Describes the sequence for starting and loading compressors to meet cooling demand.

Loading Limiting

Details how loading is limited by anticipatory capabilities to prevent safety threshold breaches.

PROGRAM KEY

High Discharge Pressure Cutout

Explains the function of the discharge pressure cutout as a backup safety.

Low Suction Pressure Cutout

Protects the evaporator from ice buildup by monitoring suction pressure against a programmable limit.

CONDENSER FAN CONTROL

8.4 CONDENSER FAN CONTROL

Details condenser fan control logic based on Discharge Pressure (DP) and Outside Ambient Temperature (OAT).

MAINTENANCE

Daily Maintenance

Outlines daily checks to be performed by the operator/customer for basic unit upkeep.

Compressor oil level

Explains how to check the compressor oil level in sight glasses during full and part load operation.

Scheduled Maintenance

Details periodic maintenance operations to be performed by a qualified Service Engineer.

TROUBLESHOOTING

COMPETENT PERSONS TROUBLESHOOTING GUIDE

A guide to troubleshoot common problems, their possible causes, and recommended actions.

LIMITED WARRANTY APPLIED SYSTEMS

York YCAS0160 Specifications

General IconGeneral
Cooling Capacity160 Tons
Compressor TypeScrew
RefrigerantR-134a
Voltage460V
Phase3
Frequency60 Hz