561923-YTG-E-0613
Johnson Controls Unitary Products 19
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
— = Not Applicable.
YHJF48S41S1
T*9(C,V)*C20 FC64D 48.0 3.72 3.78 32.8 2.58 3.73 8.50
T*9(C,V)*D20 FC/MC62D 48.0 3.72 3.78 32.2 2.52 3.74 9.00
T*9(C,V)*D20 FC64D 48.0 3.76 3.74 32.6 2.60 3.67 9.00
T*9X*C16 FC/MC62D 48.0 3.76 3.74 32.0 2.56 3.66 9.00
T*9X*C16 FC64D 48.0 3.82 3.68 32.4 2.62 3.62 9.00
T*9X*C20 FC/MC62D 48.0 3.80 3.70 32.0 2.58 3.63 9.00
T*9X*C20 FC64D 48.0 3.84 3.66 32.2 2.64 3.57 9.00
T*9X*D20 FC/MC62D 48.0 3.76 3.74 32.0 2.56 3.66 9.00
T*9X*D20 FC64D 48.0 3.80 3.70 32.4 2.62 3.62 9.00
Y*(8,L)C*C16 FC/MC62D 0.0 0.00 0.00 0.0 0.00 0.00 0.00
Y*(8,L)C*C16 FC64D 0.0 0.00 0.00 0.0 0.00 0.00 0.00
Y*(8,L)C*C20 FC/MC62D 48.0 3.76 3.74 32.0 2.56 3.66 9.00
Y*(8,L)C*C20 FC64D 48.0 3.80 3.70 32.4 2.62 3.62 9.00
Y*9C*C16 FC/MC62D 48.0 3.72 3.78 32.2 2.54 3.71 9.00
Y*9C*C16 FC64D 48.0 3.76 3.74 32.6 2.60 3.67 9.00
Y*9C*C20 FC/MC62D 48.0 3.68 3.82 32.4 2.50 3.80 9.00
Y*9C*C20 FC64D 48.0 3.72 3.78 32.8 2.58 3.73 8.50
Y*9C*D20 FC/MC62D 48.0 3.72 3.78 32.2 2.52 3.74 9.00
Y*9C*D20 FC64D 48.0 3.76 3.74 32.6 2.60 3.67 9.00
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.
3. High Efficiency Motor Furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
MODEL
FURNACE
MODEL
COIL
1
MODEL
HEATING
2
47F17F HSPF
MBH COP KW MBH COP KW STD
14.5 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
3