561923-YTG-E-0613
20 Johnson Controls Unitary Products
* Notates “Hot Heat Pump” performance. These ratings are not AHRI Listed.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
— = Not Applicable.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
HEATING CAPACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
FURNACE
MODEL
COIL
1
MODEL
HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF COP @ 47
47 OD 17 OD
14.5 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
3
YHJF60S41S1
T*(8,L)V*C20 FC/MC62D
1 1015 42.5 – – 3.20
2 1615 57.0 40.0 9.00 3.58
2* 1015 55.6 39.0 8.75 2.86
T*(8,L)V*C20 FC64D
1 1015 42.5 – – 3.26
2 1615 60.0 40.0 9.00 3.66
2* 1015 57.0 39.0 8.70 2.92
T*(8,L)X*C20 FC/MC62D
1 835 42.0 – – 2.98
2 1665 57.0 39.5 9.00 3.64
2* 835 56.5 38.5 8.85 2.62
T*(8,L)X*C20 FC64D
1 835 42.0 – – 3.06
2 1665 60.0 40.0 9.00 3.74
2* 835 56.0 39.5 8.85 2.66
T*9(C,V)*C20 FC/MC62D
1 1040 43.0 – – 3.20
2 1655 57.0 40.5 9.00 3.54
2* 1040 54.9 39.0 8.70 2.88
T*9(C,V)*C20 FC64D
1 1040 42.5 – – 3.26
2 1655 60.0 40.5 9.00 3.62
2* 1040 57.5 39.0 8.60 2.94
T*9(C,V)*D20 FC/MC62D
1 1085 43.0 – – 3.26
2 1630 57.0 40.0 9.00 3.54
2* 1085 55.6 39.0 8.65 2.94
T*9(C,V)*D20 FC64D
1 1085 43.0 – – 3.32
2 1630 60.0 40.5 9.00 3.66
2* 1085 58.0 39.5 8.65 3.00
T*9X*C20 FC/MC62D
1 1220 43.5 – – 3.38
2 1595 57.0 40.0 9.00 3.58
2* 1220 55.6 39.0 8.60 3.08
T*9X*C20 FC64D
1 1220 43.5 – – 3.48
2 1595 60.0 40.0 9.00 3.66
2* 1220 58.5 39.0 8.65 3.16
T*9X*D20 FC/MC62D
1 1240 43.5 – – 3.42
2 1645 57.0 40.0 9.00 3.60
2* 1240 55.6 39.0 8.65 3.10
T*9X*D20 FC64D
1 1240 43.5 – – 3.50
2 1645 60.0 40.0 9.00 3.70
2* 1240 58.5 39.0 8.70 3.18
Y*(8,L)C*C20 FC/MC62D
1 1015 42.5 – – 3.20
2 1615 57.0 40.0 9.00 3.58
2* 1015 55.6 39.0 8.75 2.86
Y*(8,L)C*C20 FC64D
1 1015 42.5 – – 3.26
2 1615 60.0 40.0 9.00 3.66
2* 1015 57.0 39.0 8.70 2.92
Y*9C*C20 FC/MC62D
1 1040 43.0 – – 3.20
2 1655 57.0 40.5 9.00 3.54
2* 1040 54.9 39.0 8.70 2.88
Y*9C*C20 FC64D
1 1040 42.5 – – 3.26
2 1655 60.0 40.5 9.00 3.62
2* 1040 57.5 39.0 8.60 2.94
Y*9C*D20 FC/MC62D
1 1085 43.0 – – 3.26
2 1630 57.0 40.0 9.00 3.54
2* 1085 55.6 39.0 8.65 2.94
Y*9C*D20 FC64D
1 1085 43.0 – – 3.32
2 1630 60.0 40.5 9.00 3.66
2* 1085 58.0 39.5 8.65 3.00
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.
3. High Efficiency Motor Furnaces have B.O.D (Blower on Delay) standard.