Model YORK
Unit YH3JZH018BARXAGX YH3JZH024BARXAGX
Outdoor YHUJYH018BARXA-X YHUJYH024BARXA-X
Indoor YH3MXH018BARX-GX YH3MXH024BARX-GX
Compressor
Model SNB130FGYMC-L1 SNB130FGYMC-L1
Type Rotary Rotary
Capacity W/h 13992.48 13992.48
Input W 1245 1245
Rated current(RLA) A 8.4 8.4
Locked rotor Amp(LRA) A / /
Thermal protector 120 120
Capacitor mF / /
Refrigerant oil ml 500 500
Outdoor fan motor
Model
DR-9538-706/SIC-310-52-1
"EHDS31A70AS
"
Input W
56 85
Output W
41 70
Running current A
0.25 0.4
Capacitor uF
/ /
Speed rpm
860 880
Outdoor air ow m3/h
2200 3000
Outdoor noise level (Sound power level) dB(A)
64 70
Outdoor noise level (Sound pressure level) dB(A)
54 57
Outdoor dimension
Unit (WxDxH) mm
810×288×688 860×308×730
Packing (WxDxH) mm
949×406×745 995×420×815
Outdoor weight
Net kg
43 49
Gross kg
45.5 52
Refrigerant
Type
R410A R410A
Charge g
1300 1600
Refrigerant pipe
Liquid side mm
6.35 9.52
Gas side mm
12.7 15.88
Max. refrigerant pipe
length
m
25 25
Max. difference in level m
15 15
Operation temperature range
℃
16~30 16~30
Ambient temperature range (Cooling)
℃
18~43 -10~46
Ambient temperature range (Heating)
℃
-15~24 -15~24