JOHNSON CONTROLS
31
FORM 160.76-PW5
ISSUE DATE: 09/06/2019
VARIABLE SPEED OIL PUMP DRIVE PANEL
FIGURE 13 - VARIABLE SPEED OIL PUMP DRIVE PANEL (CE)
LD29269a
VS OIL PUMP DRIVE
ENCLOSURE
PE
GND
2
5
13
8
14
11
31
15
12
10
7 9
64
1
70
64
P36
32
15
74
73
72
WIRE ENTRY VIEW
PE
PE
NEG
-RECT
L1
L2
L3
74
73
72
L3
POS
LI
70
WIRING FOR 200 THRU 346V
AND 380 THRU 600V UNITS
WHT
BLK
RED
UL
L2 L3 PE
HPCO
1(C)
2(NO)
3(NC)
1A
1
15
32
1A
VARIABLE SPEED
OIL PUMP DRIVE
L3L2L1
PE
M3
M2
M1
L2
L1
70
1
70A
PWM
EN
+V
NC
X
W
Z
Y
74
73
7270
15
12
9
6
3
1
10
7
11
14 13
8
4
5
2
1
15
J36
15
12
9
6
3
1
10
7
11
14
13
8
4
5
2
1A
J36
19
2A
G1
106
64
64
104
107
Q COMP. ONLY
1,15,70
Q COMP. ONLY
72,73,74
Q COMP. ONLY
64,72,73,
74,104,105,
106,107
74
73
105
70
15
72
1A,2A
15,64
70,G1
L2L1 L3
T1 T2 T3
A1
A2
104
105
106
2
A2
107
SUPR
LIA L2A L3A
1M
P8 AND LARGER
COMPR. ONLY
LIA L2A L3A
107
2
106
104
105
LD29269b
WIRING FOR 380 THRU 416V UNITS
PE
2
5
13
8
14
11
3
1
15
12
10
79
64
1
70
64
P36
NOTE:
SEE FIELD WIRING LABEL
(LOCATED IN THE CONTROL
PANEL), FOR FUSE SIZES
AND LOCATIONS.
32
15
HPCO
1(C)
2(NO)
3(NC)
15
32
1A
74
73
72
WIRE ENTRY VIEW
PE
PE
DS1
1
2
4 6
3 5
L2 L3
PE
PE
NEG
-RECT
L1
L2
L3
VARIABLE SPEED
OIL PUMP DRIVE
74
73
72
70
L3
POS
70
1
1A
L1
WHT
BLK
RED
X
W
ZY
ENCLOSURE
VS OIL PUMP DRIVE
CE
PE
1
70A
PWM
EN
+V
NC
M3
M2
M1
L2
L1
PE
PE
74
73
7270
15
12
9
6
3
1
10
7
11
14
13
8
4
5
2
1
15
J36
15
12
9
6
3
1
10
7
11
14
13
8
4
5
2
1A
J36
19
2A
G1
106
64
64
104
107
Q COMP. ONLY
1,15,70,
GND3
Q COMP. ONLY
72,73,74,GND4
Q COMP. ONLY
64,72,73,
74,104,105,
106,107,GND1,
GND2
74
73
105
70
15
72
1A,2A
15,64
70,G1
L2L1 L3
T1 T2 T3
A1
A2
104
105
106
2
A2
107
SUPR
LIA L2A L3A
1M
P8 AND LARGER
COMPR. ONLY
107
2
LIA L2A L3A
106
104
105
GND1,
GND2
GND3
GND4