Johnson Controls Unitary Products 27
505591-YTG-A-0909
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total
electric power input during the same period.
— = Not Applicable.
YZH06011(C)
(Y*(8,L)C/T*8V)*C20 HC60 21
1 1015 43.5 – – 3.16
2 1605 57.0 39.0 9.25 3.58
2 1015 46.0 27.6 9.00 2.74
(Y*9C/T*9V)*D20 HC60 24
1 1070 43.5 – – 3.36
2 1615 58.0 39.5 9.20 3.68
2 1070 46.4 27.5 9.00 2.95
(Y*(8,L)C/T*8V)*C20 HD60 21
1 1015 42.0 – – 2.86
2 1605 57.0 39.0 9.20 3.34
2 1015 45.1 26.9 8.80 2.39
(Y*9C/T*9V)*C20 HD60 21
1 1055 42.0 – – 2.90
2 1655 57.5 39.0 9.10 3.32
2 1055 45.0 26.9 8.60 2.47
(Y*9C/T*9V)*D20 HD60 24
1 1070 42.0 – – 2.92
2 1615 57.5 39.0 9.10 3.30
2 1070 45.4 27.0 8.70 2.47
(Y*(8,L)C/T*8V)*C20 UC60C 21
1 1015 43.0 – – 3.26
2 1605 57.5 39.0 9.30 3.66
2 1015 46.1 27.3 9.10 2.84
(Y*9C/T*9V)*C20 UC60C 21
1 1055 43.0 – – 3.24
2 1655 58.0 39.5 9.20 3.60
2 1055 46.2 27.4 9.00 2.83
(Y*9C/T*9V)*D20 UC60D 24
1 1070 43.0 – – 3.28
2 1615 58.0 39.5 9.20 3.62
2 1070 46.4 27.4 9.00 2.89
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supple-
mental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
MODEL
FURNACE MODEL
COIL
MODEL
1
W
ARI HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF
COP @
47
47 OD 17 OD
18 SEER HP WITH HIGH EFFICIENCY FURNACES
3