120
(10)
208 16.0 110.0 24.9 3.0 6.8 5.5 10.0
None - - - 58.9 64.4 70 80
E18 13.5 2 37.5 67.8 74.7 70 80
E24 18.0 2 50.0 83.5 90.3 90 100
E36 25.5 2 70.8 109.5 116.4 110 125
E54 40.6 2 112.7 161.9 168.7 175 175
230 16.0 110.0 24.9 3.0 6.8 5.5 10.0
None - - - 58.9 64.4 70 80
E18 18.0 2 43.3 75.1 82.0 80 90
E24 24.0 2 57.7 93.2 100.0 100 100
E36 34.0 2 81.8 123.2 130.1 125 150
E54 54.0 2 129.9 150.9 157.8 175 175
460 7.8 52.0 12.1 1.6 3.4 2.2 5.0
None - - - 29.2 31.4 35 35
E18 18.0 2 21.7 37.6 40.3 40 45
E24 24.0 2 28.9 46.6 49.3 50 50
E36 34.0 2 40.9 61.6 64.4 70 70
E54 54.0 2 65.0 75.5 78.2 80 90
575 5.7 38.9 8.9 1.4 2.4 1.8 4.0
None - - - 21.9 23.7 25 25
E18 18.0 2 17.3 29.7 31.9 30 35
E24 24.0 2 23.1 36.9 39.1 40 40
E36 34.0 2 32.7 48.9 51.1 50 60
E54 54.0 2 52.0 60.0 62.2 70 70
150
(12.5)
208 22.4 149.0 35.0 2.1 9.6 5.5 10.0
None - - - 78.4 83.9 100 100
E18 13.5 2 37.5 78.4 83.9 100 100
E24 18.0 2 50.0 87.0 93.8 100 100
E36 25.5 2 70.8 113.0 119.9 125 125
E54 40.6 2 112.7 165.4 172.2 175 175
230 22.4 149.0 35.0 2.1 9.6 5.5 10.0
None - - - 78.4 83.9 100 100
E18 18.0 2 43.3 78.6 85.5 100 100
E24 24.0 2 57.7 96.7 103.5 100 110
E36 34.0 2 81.8 126.7 133.6 150 150
E54 54.0 2 129.9 154.4 161.3 175 175
460 10.6 75.0 16.5 1.3 4.7 2.2 5.0
None - - - 38.6 40.8 45 50
E18 18.0 2 21.7 39.2 41.9 45 50
E24 24.0 2 28.9 48.2 51.0 50 60
E36 34.0 2 40.9 63.2 66.0 70 70
E54 54.0 2 65.0 77.1 79.8 90 90
575 7.7 54.0 12.0 0.7 3.6 1.8 4.0
None - - - 27.6 29.4 35 35
E18 18.0 2 17.3 31.2 33.4 35 35
E24 24.0 2 23.1 38.4 40.6 40 45
E36 34.0 2 32.7 50.4 52.6 60 60
E54 54.0 2 52.0 61.5 63.7 70 70
1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.
ZR078-150 standard motor - with powered convenience outlet (continued)
Size
(tons)
Volt
Compressors
(each)
OD fan
motors
(each)
Supply
blower
motor
Pwr exh
motor
Pwr
conv
outlet
Electric heat option
MCA
1
(amps)
MCA
1
with pwr
exh (amps)
Max fuse
2
/
breaker
3
size (amps)
Max fuse
2
/
breaker
3
size with
pwr exh
(amps)
RLA LRA MCC FLA FLA FLA FLA Model kW Stages Amps