This parameter defines when the red LED will indicate events. Disabling all indications may extend
battery life. Value 0 means no indications.
Size: 1 Byte, Default Value: 7 (values 1 + 2 + 4 summarized)
Setting
Description
1
Open/Close Status Change
2
Wake Up
4
Device Tampering
Parameter 5: Range Test after double click
Allows to enable the activation of a Z-Wave range test. Double-clicking the tamper will start the process.
As a result, the GREEN LED will blink two times in case of success and the RED LED will blink two times in
case of failure.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Disabled
1
Enabled
Parameter 6: 2nd Association Group Trigger
This parameter defines the status of the magnet switch that causes sending a BASIC command to all
devices of Association Group 2.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Switch after Open and Close
1
Switch after Open
2
Switch after Close
Parameter 7: Command Sent to Devices of Association Group 2
This parameter defines which commands is sent to 2nd Association Group
Size: 1 Byte, Default Value: 2
Setting
Description
0
On
1
Off
2
On and Off
Parameter 8: BASIC command value sent to 2nd Association Group on On event
This is the BASIC command value sent in case of On event.