9) LIFTING SWITCH
Status of the lifting switch.
- ON / +VB = active entry of closed switch.
- OFF / GND = non active entry of open switch.
10) 1ST SPEED SWITCH
Status of the first speed switch of the pump.
- ON / +VB = active entry of closed switch.
- OFF / GND = non active entry of open switch.
11) 2ND SPEED SWITCH
Status of the second speed switch of the pump.
- ON / +VB = active entry of closed switch.
- OFF / GND = non active entry of open switch.
12) 3RD SPEED SWITCH
Status of the third speed switch of the pump.
- ON / +VB = active entry of closed switch.
- OFF / GND = non active entry of open switch.
13) 4TH SPEED SWITCH
Status of the fourth speed switch of the pump.
- ON / +VB = active entry of closed switch.
- OFF / GND = non active entry of open switch.
14) HYDRO SPEED REQ.
Status of the hydro speed request of the pump.
- ON / +VB = active entry of closed switch.
- OFF / GND = non active entry of open switch.
15) CUTBACK SWITCH
The level of the Speed Reduction Microswitch.
- ON / GND = active entry of speed reduction microswitch.
- OFF / +VB = non active entry of microswitch.
16) VOLTAGE BOOSTER
This is the booster of the voltage supplied to the motor in load condition; it is
expressed in a percentage of the full voltage.
17) BATTERY VOLTAGE
Level of battery voltage measured at the input to the key switch.
18) BATTERY CHARGE
The percentage Charge level of the battery.
Page - 46/64 ADEZP0AE - AC-2 INVERTER - User Manual