H2B USER'S MANUAL - 550145G Page 21/60
ing time parameter.
SOFT BRAKING On No Soft braking.
Off Soft braking activated.
AUX FUNCTION none No Aux function.
bimotor contactor AUX G7 output is activated
when turning from off status to running status and at
the beginning of regenerative braking, and it is
switched off when PWM is greater than 20%, both
statuses.
hydrocontactor The output AUX G7 com-
mands the hydrodrive contactor. It should be active
during both forward and backward directions and
during release braking. The turning OFF delay is
programmable at "AUXILIARY TIME".
HYDRO KEYON (H2G softw.only) On Hydrodrive activation at key-
on. Activation time is defined
by param. AUXILIARY TIME.
Off Hydrodrive disable at key-on.
MAIN CONTACTOR present Main contact. present on G5.
running status G5 is ON during functions
(except descent).
- SELECTION OF BATTERY VOLTAGE: ADJUSTMENT MENU
Makes it possible to set the nominal voltage of the battery for handling the charge status
and tester functions.
With "BATTERY TYPE" it is possible to select the nominal voltage.
With "ADJUST BATTERY" it is possible to make a fine adjustments of battery voltage.
- SPECIAL ADJUST
PARAM CHANGE EN (H2G softw.only) On Parameters modification is
allowed.
Off Parameters are locked.
Modification is not allowed.
AUX FUNCTION #1(Only traction) On Load H.M. from Mdi.
Off No load of H.M. from Mdi.
ADJUSTMENT #1 (Only traction) 0 ... 9 Set the maximum of the battery
discharge curve.
ADJUSTMENT #2 (Only traction) 0 ... 9 Set the minimum of the battery
discharge curve.
SET TEMPERATURE Fine adjustment of the chopper
temperature.
- HARDWARE SETTINGS
SET CURRENT Sets the current for tester to 400A
or 600A.