12) HYDRO TIME = Hydrodrive delay time. If set at 0, there is no delay; thus the hydrodrive
input can be handled as a 5th speed.
13) 1ST SPEED COARSE = Speed no. 1, coarse adjustment.
14) 1ST SPEED FINE = Speed no. 1, fine adjustment.
15) 1ST SPEED COMP. = Compensation speed no.1.
16) 2ND SPEED COARSE = Speed no. 2, coarse adjustment.
17) 2ND SPEED FINE = Speed no. 2, fine adjustment.
18) 2ND SPEED COMP. = Compensation speed no.2.
19) 3RD SPEED COARSE = Speed no. 3, coarse adjustment.
20) 3RD SPEED FINE = Speed no. 3, fine adjustment.
21) 3RD SPEED COMP. = Compensation speed no.3.
22) 4TH SPEED COARSE = Speed no. 4, coarse adjustment.
23) 4TH SPEED FINE = Speed no. 4, fine adjustment.
24) 4TH SPEED COMP. = Compensation speed no.4.
25) MAX SPEED LIFT (H2G softw.only) = Maximum speed for request handled by pot.
26) MIN. VALVE VOLT. = Minimum voltage applied on the proportional solenoid valve.
27) MAX. VALVE VOLT. = Maximum voltage applied on the proportional solenoid valve.
6.1.4 Adjustment chart
PARAMETER PROGRAMMED LEVEL
UNIT 0 1 2 3 4 5 6 7 8 9
ACCELERATION DELAY* Sec. 0.15 0.24 0.39 0.50 0.63 0.74 0.86 0.97 1.09 1.22
EV. ACCELER DELAY Sec. 0.39 0.63 0.71 0.81 0.97 1.05 1.27 1.36 1.46 1.54
DECELER DELAY Sec. 0.06 0.13 0.19 0.25 0.31 0.38 0.44 0.50 0.56 0.62
EV. DECELER DELAY Sec. 0.30 0.60 0.70 0.78 0.95 1.04 1.26 1.36 1.43 1.53
I MAX. (H2 600) Amp. 300 333 367 400 433 467 500 533 567 600
I MAX. (H2 500) Amp. 250 278 306 333 361 388 416 444 472 500
I MAX. (H2 400) Amp. 200 222 244 266 289 311 333 355 378 400
SPEED COARSE (ALL) % VBatt. 0 11 22 33 44 55 66 77 88 100
SPEED FINE (ALL) % VBatt. 0 1.2 2.4 3.6 4.8 6.05 7.3 8.5 9.7 10.9
COMPENSAZIONE (ALL) K (I) 10 20 30 40 50 60 70 80 90 100
CREEP SPEED %VBatt. 0 1.9 3.9 5.9 7.8 9.8 11.7 13.7 16.6 17.6
WEAK DROPOUT %IMax. 10 20 30 40 50 60 70 80 90 100
HYDRO TIME sec. 0 0.5 2 4 7 9 12 14 17 20
MIN VALVE VOLT %VBatt. 7.4 11.3 15.2 19.2 23.1 27.0 31 35 39 43
MAX VALVE VOLT %VBatt. 56 60 64.5 70 74 78.5 83.5 88 92.5 97.5