8 Z4Mplus and Z6Mplus Maintenance Manual 13358L Rev. 1 11/17/03
Section 1 System Description
General Specifications
Electrical Requirements
Autoselect 90 to 264 VAC; 48 to 62 Hz
5 Amps for entire AC voltage range
25 Watts standby power consumption
200/300/350/450 Watts maximum power consumption (printing full-width,
100% black at 6 ips)
Agency approvals: IEC60950, EN55022 Class B, EN55024, EN61000-3-2,
EN61000-3-3.
Product markings: cULus, CE Marking, FCC-B, ICES-003, VCCI, C-Tick,
NOM, IRAM, CCC, GOST-R, BSMI.
Environmental Operating Ranges
Physical Characteristics Z4Mplus Z6Mplus
Height 13.32 in. (338 mm) 13.32 in. (338 mm)
Width 10.93 in. (278 mm) 13.43 in. (341 mm)
Depth 18.69 in. (475 mm) 18.69 in. (475 mm)
Weight (without options) 32.4 lbs. (15 kg) 34.7 lbs. (16 kg)
Temperature
Operating
Thermal Transfer: +40
o
F to +104
o
F (+5
o
C to +40
o
C)
Direct Thermal: +32
o
F to +104
o
F (0
o
C to +40
o
C)
Storage
–40
o
F to +140
o
F (–40
o
C to +60
o
C)
Non-condensing relative
humidity
Operating 20% to 85%
Storage 5% to 85%