TECHNICAL MANUAL
HeatSink
True-Cycling Refrigerated
Compressed Air Dryers
HSF Models
1000-1600 SCFM
ZEKS Compressed Air Solutions
1302 Goshen Parkway
West Chester, PA 19380
Phone: 610-692-9100
800-888-2323
Fax: 610-692-9192
Web: www.zeks.com
Form: TM 1000-1600HSF-DPC-0513
DPC
Patent No.: 6,186,223
NOTICE
Those operating the machine or performing
maintenance should read and understand the
decals positioned on the machine and
contents of this Technical Manual.
Ensure that this Technical Manual is not
removed permanently from the machine.
TM

Questions and Answers

  • D
    David CarrollNov 2, 2025
    What to do if there is moisture downstream in my ZEKS 1200HSFA400?
    • M
      Melissa WatkinsNov 2, 2025
      If you notice moisture downstream in your ZEKS Air Conditioner, several factors could be the cause. First, there might be a drain failure or the timer needs adjustment. Try depressing the “TEST” button. If the drain valve operates, adjust the timing as described in Section 6.3. If 'DRAIN TEST' is displayed, but the valve doesn't open, make sure the wiring connections are secure and power is being applied to the solenoid coil. If it still doesn’t open, clean the valve as described in the Maintenance Section of this manual. If the display doesn't show 'DRAIN TEST', contact your distributor. Other potential causes include excessive flow (check inlet and outlet pressures and system design capacity), a dryer by-pass valve not closed (correct the cause of excessive flow and close the by-pass val...

Summary

Receiving and Inspection Procedures

Safety and Operation Precautions

Personnel Safety and Procedures

Ensures only qualified personnel perform maintenance and follow operating safety rules.

Operational Safety Protocols

Covers safe operating practices, including electrical safety and pressure relief procedures.

System Integrity and Refrigerant Handling

Addresses safe handling of refrigerant and maintaining system integrity via guards and inspections.

Principles of Dryer Operation

Dryer Controls, Parameters, and Alarms

Details the DPC controller, user interface, parameters, set points, and alarms.

Installation and Initial Start-Up

Initial Startup Procedures and Sequence

Outlines the step-by-step sequence for initial dryer startup.

Scheduled Maintenance Procedures

Technician Mode Operations

Entering and Navigating Technician Mode

Describes how to access and navigate the protected technician mode for advanced settings.

Troubleshooting Guide

Problem;Action Guide and Introduction

Provides a guide to identifying and resolving common dryer problems.

Wiring Diagrams

ZEKS 1200HSFA400 Specifications

General IconGeneral
AirflowNot Available
PowerNot Available
RefrigerantR410A
Power Supply220V, 50Hz
Cooling Capacity12000 BTU/h