Questions and Answers

  • J
    Jody MorrisAug 14, 2025
    Why does my ZEKS Eclipse 600ZPA Dryer have an elevated dew point?
    • E
      Erin McmillanAug 14, 2025
      An elevated dew point in your ZEKS Dryer can stem from several causes. It may be due to an insufficient purge rate, so check the purge flow settings and piping for obstructions, cleaning the piping and muffler if needed. Also, inlet air pressure below the design condition, a flow rate higher than the design condition, or an inlet temperature exceeding 120F can contribute to this issue. Check the pressure source and system for leaks, verify the flow rate, and inspect/service the aftercooler. Finally, entrained water entering the desiccant bed or desiccant contaminated by oil could be the reason. In this case, check the air/moisture separator, prefilter, and drains, replacing the dryer desiccant if necessary. Consider installing a suitable prefilter.
  • D
    Donald RosarioAug 17, 2025
    What to do if there is excessive pressure drop in my ZEKS Eclipse 600ZPA?
    • C
      christopher94Aug 18, 2025
      If you're experiencing an excessive pressure drop in your ZEKS Dryer, it could be due to an excessive flow rate. Check the flow rate and determine the cause for the increased air demand. Alternatively, the inlet pressure may be below the design condition, so you should check the pressure source.
  • W
    watsonbradleyAug 20, 2025
    How to fix a ZEKS Eclipse 600ZPA Dryer that fails to shift?
    • V
      Vincent BurnettAug 20, 2025
      If your ZEKS Dryer isn't shifting, begin by checking the power input to ensure there's no issue with the power supply. Then, inspect the solenoid valve for any defects. Also, verify that there is pilot air by checking the pilot air line and ensuring the control air line filter is clean. Lastly, inspect the pilot-operated diaphragm valve seat for failure, replacing seals as needed.
  • B
    Bryan OchoaAug 25, 2025
    What does it mean if the Blue Moisture Indicator (BMI) on my ZEKS Dryer indicates a high moisture level?
    • L
      leonardjamesAug 25, 2025
      If the Blue Moisture Indicator (BMI) on your ZEKS Dryer indicates a high moisture level, it could be due to an elevated dew point. Refer to the corrective actions for 'Elevated Dew Point'. Also, if the BMI is wet, depending on the desiccant saturation, it could take a week or more of continuous use for it to switch back to its blue (dry) state.
  • J
    jose80Aug 27, 2025
    What to do if my ZEKS Eclipse 600ZPA Dryer fails to pressurize?
    • N
      Nicole GarzaAug 27, 2025
      If your ZEKS Dryer fails to pressurize, it may be due to a faulty purge valve. Check that the repressurization circuit is sending a control signal and inspect the purge valve and its solenoid valve.
  • E
    Emily WatkinsAug 30, 2025
    Why does my ZEKS Eclipse 600ZPA Dryer fail to purge?
    • T
      Toni GarzaAug 31, 2025
      If your ZEKS Dryer fails to purge, it could be because the purge valve does not open or is stuck in the closed position. Check the purge valve and its solenoid valve, repairing or replacing them if necessary. Also, verify that the repressurization circuit is sending a control signal.
  • Z
    zwrightSep 3, 2025
    Why is my ZEKS Dryer depressurizing too rapidly?
    • A
      Amanda WilliamsSep 3, 2025
      If your ZEKS Dryer is depressurizing too rapidly, it could be that the purge valve doesn't close, and the dryer is repressurizing through the inlet valve. Check the purge valve and its solenoid valve.
  • A
    Amber GrantSep 6, 2025
    How to resolve excessive back pressure in the regenerating tower (above 5 psig) of my ZEKS Eclipse 600ZPA Dryer?
    • B
      Brian DavisSep 6, 2025
      Excessive back pressure in the regenerating tower (above 5 psig) of your ZEKS Dryer can occur if the purge muffler does not pass air, indicating it is dirty and needs replacement. Alternatively, it could be that the purge muffler passes too much air because air is leaking across the valve. In this case, check the inlet valve and outlet check valves, and verify that the inlet valve is closed to the purging tower (0 psig tower).
  • S
    Sherry MccartySep 10, 2025
    What causes excessively high pressure at the purge gauge on the right tower of my ZEKS Dryer?
    • R
      robert19Sep 10, 2025
      An excessively high pressure reading at the purge gauge on the right tower of your ZEKS Dryer may be due to improper calibration. Reset the gauge when the right tower is online.

Summary

2.0 Abbreviated Warranty

4.0 Receiving and Inspection

4.1 Inspection and Handling

Inspect the unit for damage upon receiving and follow proper unpacking and handling procedures.

5.0 Safety and Operation Precautions

General Safety Guidelines

Observe safety precautions including qualified personnel, reading instructions, and proper maintenance procedures.

6.0 Principles of Operation

6.4 Setting Regeneration Air Flow

Manually set purge air flow to ensure proper dryer performance and dew point.

7.0 Alarms and Indicators

8.0 Installation and Start-Up

8.7 Start-Up Procedure

Follow start-up procedures, pressurize slowly, check for leaks, and verify system operation through cycles.

9.0 Maintenance and System Check

9.1 Scheduled Maintenance Overview

Covers daily, semi-annual, annual, and bi-annual tasks for optimal performance and longevity.

10.0 Troubleshooting

13.0 Wiring Diagram

14.0 Flow Diagram

17.0 Replacement Parts Diagram

18.0 Replacement Parts List

ZEKS Eclipse 600ZPA Specifications

General IconGeneral
BrandZEKS
ModelEclipse 600ZPA
CategoryDryer
LanguageEnglish

Related product manuals