Maintenance
4) CARBURETOR
Items Standard Limit Measuring Device Remarks
Metering Lever set (mm) 1.65 ± 0.16 Vanier
Inlet Valve Opening Pressure (kg/cm
2
) 1.3~2.3 Leak Tester
Inlet Valve Closing Pressure (kg/cm
2
) 0.7~1.7 Leak Tester
5) IGNITION SYSTEM
Items Standard Limit Measuring Device Remarks
Spark Plug Air Gap (mm) 0.6~0.7 0.7 Thickness Gauge
Ignition Coil/Flywheel Air Gap (mm) 0.5 0.6 Thickness Gauge
1.76 kΩ — Sparkplug Wire – Stop Core
Coil Resistance (Ω) 294 Ω — Volt Meter Stop Core – Coil Core
1.46 kΩ — Coil Core – Sparkplug Wire