Installation
Gas inlet – Use two wrenches (It will break if held with one wrench at the gas water heater
outlet)
Use a swivel fitting as supplied
NB - Hot water outlet – It is recommended to fit a FULL-BORE water valve. Do NOT use flex type
toilet connectors. The flow will be restricted and will result in gas water heater failure
Cold water inlet – Flush the cold-water pipe before connecting to free the pipe of dirt. When
using water from a storage tank, it is recommended to fit an inline water filter.
Do NOT use flex type toilet connectors.
Preparation
The gas water heater ignition function is powered by two large 1.5V. DC (Type D) torch
batteries. Please insert the correct way as indicated on the battery housing.
Batteries are NOT included.
Ignition
Open the gas at the cylinder valve and the gas valve after the regulator.
Open the warm water tap. The electronic ignitors will light up the main burners after 6 to 10
seconds.
First time ignition after installation, or when changing the cylinder, might take longer as there
will be air inside the gas pipe. Repeat if ignition is not obtained within the 10 seconds.
NB - Remember that the installer must by law commission your newly installed water heater in
your, or your representative’s presence, before you sign off the installation.