38
MAINTENANCE INSTRUCTIONS
S21 S28 S8
INNER SAFETY AIR FILTER ELEMENT
EXCHANGE
remove the wing nut of inner safety air
filter element
remove the safety air filter element
Inner safety air filter element can
not be regenerated!
It must be exchanged in the following
cases:
- if the main air filter element is damaged
- after 5
th
maintenance of air cleaner
- minimally once per 2 years
AIR FILTER ELEMENT REASSEMBLY
Be careful at the air filter element re-
assembly:
- keep the contact surfaces clean
- air filter elements must not be
deformed and must not vibrate after
assembly
- rubber sealing must be fitted properly
round the complete circumference, the
proper tightness of the complete
cleaner must be assured after reas-
sembly of air filter cover
CLOGGING INDICATOR RESET
Reset the clogging indicator after
dry air cleaner maintenance.
push the push button on the indicator
body (2a)
you will mechanically release the in-
dicator lock of red field indicating
clogging
indicator is again in function (2b)