Section 4. Programming
4-14
Installation Tests
These commands are used to set transmit and receive levels during initial
installation, and later on for trouble shooting. They are described in Section 5,
Installation.
92# Transmit Level Test
93# Repeat Audio Test / Receive Level Adjustment
94# Enable High-Speed Phone Programming (This
command disables all prompt and confirmation
tones for an automated program upload.)
Exit Program Mode
99# Exit Program Mode
TWO-TONE TABLES
Two-Tone Timing
Timing # 1st Gap 2nd Group Type
0 1.0 0 3.0 8.0 GE Std
1 0.4 0 0.8 8.0 Mot Tone Only
2 1.0 0 3.0 6.0 NEC-B
3 1.0 .25 3.0 6.0 NEC-A
4 1.0 0 1.0 4.0 NEC-C
5 0.4 0 0.8 4.0 NEC-M
6 0.5 0 0.5 3.0 NEC-L
7 0.4 0 0.4 3.0 NEC-D