Quick Guide UFR1001E
updated: 2019-04-24/Ba
from Firmware: 0-10
UFR1001E 12420-0751-13 Seite
1
/ 8 www.ziehl.de
- NA-protection according to VDE-AR-N 4105:2011+2018-11, power generators at the low
voltage grid, TAR medium voltage VDE-AR-N 4110:2018-11
- for use in power generators at the medium voltage grid according to BDEW
- with selectable vector shift detection and Rate of Change of Frequency (ROCOF,df/dt)
Detailed operating manual see: https://www.ziehl.com/en/products/?view=detail&detail=54
New, Firmware 0-10: default setting program 2 for low voltage VDE-AR-N 4105:2018-11
4 new programs (11-14) for medium voltage according to 4110:2018-11, new test mode
(display of the firmware function 8Info8 8fnr 8 or press “Set” for >10 s)
General Notes
Compliance with the following instructions is mandatory to ensure the functionality and safety of the
product. If the following instructions given especially but not limited for general safety, transport, storage,
mounting, operating conditions, start-up and disposal / recycling are not observed, the product may not
operate safely and may cause a hazard to the life and limb of users and third parties.
Deviations from the following requirements may therefore lead both to the loss of the statutory material
defect liability rights and to the liability of the buyer for the product that has become unsafe due to the
deviation from the specifications.
Operating controls
1
Test button
Press
shortly
Display test-menu: Relay K1 (8tst18) or K2 (8tst28) can be tested independently. (3min
without a button is pressed = go back to the normal mode)
2
LEDs Frequency / voltage, above / below threshold (red)
ON, 8AL 8or 8AL M8
Above / below threshold
Flashing, 8AL 88or 8AL M8
OFF-delay 8dof 8 active
3
LED Vektor shift (VSR, red)
ON, 8AL 8
Threshold value for vector shift exceeded
Flashing, 8AL 8
OFF-delay 8dof 8 active
4
LEDs Relay status (yellow)
OFF
Relays de-energized
ON
Relays energized
5
Digital display 4-digit (red)
Depending on program, display of current voltage, frequency, vector shift, average value
Display of alarm message 8AL 8, 8aL M8
Display of error with error code e.g. 8Err98
6
LED Time (yellow)
ON
A time is displayed
7
Backmost decimal point (red)
OFF
Display mode
Lightning
Menu mode
Flashing
Configuration mode