SECTION 8 LCD SCREEN
8.7.4 Energy modes
This mode allows the HydroTap
G4 to go into energy saving mode. There are
two options available: sleep mode and on/off mode.
It is recommended to recalibrate the lux sensor after selecting any of the
lux sensor options from the sleep mode menu. (See page 20 ,Lux sensor
calibration).(Classic, Arc / Cube only).
Sleep Mode* Light
level
Time
delay
State Boiler Chiller
2 Hours > 68
0
C
N/A 2 Hr Sleep 68
0
C ON
2 Hours > OFF
N/A 2 Hr OFF OFF OFF
Lux Sensor > 68
0
C
Dark N/A Sleep 68
0
C ON
Lux Sensor > OFF
Dark N/A OFF OFF OFF
Lux Sensor or 2 Hr > 68
0
C
Dark 2 Hr Sleep 68
0
C ON
Lux Sensor or 2 Hr > OFF
Dark 2 Hr OFF OFF OFF
Disable
N/A N/A ON ON ON
In sleep mode the unit will go to “Sleep” after a 2hr period of inactivity. The
boiling water will gradually drop to either 68°C or room temp, as shown in the
table below and the chilled water will be ON or OFF.
Press the [MENU] button for main
menu.
Press the [Settings] button.
Enter your 4-digit password and
press [Enter].
Press the [Energy Modes] button.
Press the [Sleep Modes] button
then in the next screen, use the
up and down arrow to select sleep
mode from the 7 options in the
table below.
To activate sleep mode
* Full list shown, available modes dependant upon model purchased.