IMPORTANT SAFETY INFORMATION
To avoid contact with electrical current:
Never install an Ethernet connection in wet locations unless that connector is
specifically designed for wet locations.
Do not place Ethernet wiring or connections in any conduit, outlet or junction box
containing electrical wiring.
Installation of inside wire may bring you close to electrical wire, conduit, terminals
and other electrical facilities. Extreme caution must be used to avoid electrical
shock from such facilities. Avoid contact with all such facilities.
Ethernet wiring must be at least 2 m from bare power wiring or lightning rods and
associated wires, and at least 15 cm from other wire (antenna wires, doorbell
wires, wires from transformers to neon signs), steam or hot water pipes, and
heating ducts.
ELECTROMAGNETIC COMPATIBILITY
In proper state and when operated properly, the product complies with all the
requirements in respect of interference radiation according to EN 301 489-17, EN
301 489-1 and EN 300 328. The connections conducting HF signals must neither be
manipulated nor damaged.