GENERAL CABINET REQUIREMENTS
1⁄4" (6 mm) space is required between the side of the appliance and an adjacent wall
or cabinet door when installed at the end of a cabinet run.
The cabinet base must be flat and capable of supporting the weight (roughly 90 lb,
41 kg) of your appliance when in use.
The door will overlap the furniture below by approx 3/16" (5 mm) when opened.
There must be an air gap of at least 1/4" (6 mm) between the appliance and the cabinet
walls when the appliance is installed, i.e. 1/8" (3 mm) each side.
A gap of at least 1 3/4" (44 mm) is needed between the wall and the back of the unit
for ample space for the power cord.
MWO24
MWO30
Cabinet Requirements