DIAG.030.A - EN - 2019-12 1
Technical procedure
• Alpha®iQ cleaners are not compa ble with:
-
the "Diag Box" diagnos c unit;
- the "Full Test Diag" diagnos c so ware;
• The diagnosis described in this procedure is available using a masked func on from the control box delivered
with the cleaner.
1. Cleaner diagnostics
- Test to be conducted out of the water.
- Connect the cleaner to the control box delivered with the cleaner.
- Connect the control box's power cable.
- Turn the cleaner on its back (wheels facing upwards) when rota ng the wheels forwards and backwards (trac on
test)
• On the control box, press and hold for 10 seconds.
• Quick mode (fl oor only) fl ashes by default . For control boxes with a screen, the message "diAG" is displayed
at the same me.
• Press to start the cleaner's diagnos cs. The diagnos cs process will review the following 5 points in the given
order and will stop as soon as an error is iden fi ed:
• During the cleaner's diagnos cs sequence, do not look directly at the light beam coming from the motor unit.
COM (Communica on)
tr1 (Trac on 1)
tr2 (Trac on 2)
PMP (Pump Motor)
SEnS (Sensor Unit) (depending on the
model)
"Wait for the test to automa cally end"
During the test:
• All of the control box's LEDs are fl ashing.
• The motor unit's LEDs are lit.
• The sensor unit's LED fl ashes green and turns orange when tes ng the sen-
sor unit.
• Follow the instruc ons, see “2. Cleaner diagnos cs results”.
Troubleshoo ng
Alpha™ iQ
Cleaner and control box diagnos cs