DIAG.030.A - EN - 2019-12 1
Technical procedure
Alpha®iQ cleaners are not compa ble with:
-
the "Diag Box" diagnos c unit;
- the "Full Test Diag" diagnos c so ware;
The diagnosis described in this procedure is available using a masked func on from the control box delivered
with the cleaner.
1. Cleaner diagnostics
- Test to be conducted out of the water.
- Connect the cleaner to the control box delivered with the cleaner.
- Connect the control box's power cable.
- Turn the cleaner on its back (wheels facing upwards) when rota ng the wheels forwards and backwards (trac on
test)
On the control box, press and hold for 10 seconds.
Quick mode (fl oor only) fl ashes by default . For control boxes with a screen, the message "diAG" is displayed
at the same  me.
Press to start the cleaner's diagnos cs. The diagnos cs process will review the following 5 points in the given
order and will stop as soon as an error is iden ed:
During the cleaner's diagnos cs sequence, do not look directly at the light beam coming from the motor unit.
COM (Communica on)
tr1 (Trac on 1)
tr2 (Trac on 2)
PMP (Pump Motor)
SEnS (Sensor Unit) (depending on the
model)
"Wait for the test to automa cally end"
During the test:
All of the control box's LEDs are fl ashing.
The motor unit's LEDs are lit.
The sensor unit's LED fl ashes green and turns orange when tes ng the sen-
sor unit.
Follow the instruc ons, see “2. Cleaner diagnos cs results”.