20X Bar-tacking and Button Sewing Machine(LCD N) Service Parameter Setting
72
K166
The middle pressure foot with synchronous
-10~10
0
Only if the K02
parameter is set
to 3
K172
Set stitch number for thread breakage
detection
010
0
Value bigger
than 0 means
the stitch
number after
thread breakage
before
emergency stop
0 means thread
breakage
detection is off.
K174
Sensor availability at the cutter position
0: forbidden
1: in use
1
K180
(X)motor find origin mode
0External sensor
1Motor encoder
2The master control
0
K181
(Y)motor find origin mode
0External sensor
1Motor encoder
2The master control
0
K182
(C)motor find origin mode
0External sensor
1Motor encoder
2The master control
0
K183
(P)motor find origin mode
0External sensor
1Motor encoder
2The master control
0
K221
Button locating pin X coordinates
-600~600
Units:0.1mm
0
K222
Button locating pin Y coordinates
-600~600
Units:0.1mm
0
K227
Main Shaft Motor Type
0: 0830-F11
1: 0830-F01
0
Effective after
restart
K228
Spindle stop lock shaft function
0:Dont lock shaft
1:Lock shaft
0
K241
Function Selection
0: Bar-tacking
5: Pattern bar-tacking
7: Button sewing
0
Note: the above parameters are for the use of repairers only and user should not change them without