System Specifications:
Physical
Mounting: Supplied dock and RAM®
mount
Weight: 1.5 pounds
Dimensions: 8.0 x 5.3 x 1.0 inches
8.4 x 5.4 x 2.1 inches with dock
Environmental
Operating Temperature
Docked: -4˚F to 140˚F (-20˚C to 60˚C)
Operating Temperature
Un-Docked: 14˚F to 140˚F (-10˚C to 60˚C)
Storage Temperature: -40˚F to 140˚F (-40˚C to 60˚C)
Charge Temperature: 32˚F to 122˚F (0˚C to 50˚C)
Humidity: 95% R.H., non-condensing
Shock/Vibration: SAE J1455, MIL-STD-202G
EMC/EMI: SAE J1113
ESD: IEC 61000-4-2
IP Rating: 54
RFID
Frequency: 125 kHz
Read Range: 0 to 1 inch
Electrical
Battery: 2760 mAh lithium ion
VOLTAGE
Operating Voltage: 8 VDC to 30 VDC
vehicle battery
Typical current draw
State Draw
Charge disabled <1 mA
Charge enabled, Zonar Connect off -
23 - 300mA
Typical normal Zonar Connect operation
400 - 600 mA Worst case 1.0 A
The Zonar Connect is configured to only charge the
internal battery when the vehicle’s engine is on and
up to 30 minutes after the engine has been turned off.