EasyManua.ls Logo

Zte ZXA10 C300 - Common Interface Card Running Status Check; Power Interface Card Running Status Check

Zte ZXA10 C300
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ZXA10C300MaintenanceManual
IndicatorStatusDescription
GreenLEDashesslowly
everytwoseconds.
Thecardisworkingproperly.
RedLEDisON.Cardhardwarefailure
RedLEDashesslowly
everytwoseconds.
Thiscardshouldnotbeinsertedinthisslot.
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionoflinecarddoesnotmatch
thatoftheswitchingandcontrolcard.Theservice
isnormal.
OFFTributaryisnotconguredonNM.
GreenLEDisON.Tributaryisnormal.
RedLEDisON.HighorderalarmoccursonservicelinefromTAA
to2Mcard.
ALM
YellowLEDisON.TheconguredtributaryE1linealarmoccurs.
2.2.9CommonInterfaceCardRunningStatusCheck
TheZXA10C300usestheCICKcommoninterfacecard.
Table2-17describesindicatorsoftheCICKcardpanel.
Table2-17IndicatorDescriptionoftheCICKCard
IndicatorStatusDescription
GreenLEDashesslowly.Thecardisworkingproperly. RUN
RedLEDisON.Thecardhardwarefailure
GreenLEDisON.Theinterfaceconnectionisproper,butnodatais
sendingorreceiving.
ETH
GreenLEDashes.Theinterfaceissendingorreceivingdata.
2.2.10PowerInterfaceCardRunningStatusCheck
ZXA10C300usesthePRWGpowerinterfacecard.
Table2-18liststheindicatordescriptionsofthepowerinterfacecardpanel.
Table2-18IndicatorDescriptionofPowerInterfaceCardPanel
IndicatorStatusDescription
PWRGreenLEDisON.Externalpowerinputisavailable.
RUNGreenLEDisON.Thecardisrunningproperly.