ZXA10C300MaintenanceManual
Prerequisite
lThepatchlesforupdatingaresavedunderthespecieddirectorywhentheFTPtool
iscongured.
lTheFTPservicesontheZXA10C300devicehavebeencongured.
lTheNEdataoftheZXA10C300devicehasbeenbackedup.
lTheNEtobeupgradedmustnothaveanymajoralarm,otherwiseitmayinuence
theupgrade.Ifthereisany,clearthefaultrstandthenupgradetheNE.
Context
Thefollowingupgradingstepsareapplicableforbothlocalupgradingandremote
upgrading.
Patchupgradingfocusesontheservicecardorthecontrolandswitchingcard,andis
irrelevanttotheslotnumber.
Steps
Upgradethepatchlefortheservicecard.
Note:
Beforetheupgradingpatch,youneedtomakesuretheservicecardisinINSERVICE
status.
1.Downloadthepatchle.(TaketheGTGOEcardastheexample.)
ZXAN##filedownloadpatchGTGOEV120P1T6_r2.pat
2.Upgradethepatchle.
ZXAN#patchactiveGTGOEV120P1T6_r2.pat
3.(Optional)Restartthecard.
ZXAN#resetslotno7
Note:
Aftertheupgradingpatch,itisusuallynotnecessarytorestartthecard.Aboutthe
cardrestarting,youcanrefertothecorrespondingupgradenotefordetails.
Upgradethepatchforthecontrolandswitchingcard.
4.Downloadthepatchle.(TaketheSCXNcardastheexample.)
ZXAN##filedownloadpatchSCXNV120P1T6_r0.pat
6-8