ZXR10AlarmHandlingManual
latedsubeventlist.Nowthemembernumberisfullandthisalarm
appears.
Recommended
Operations
Itisaprompt.Thereisnoneedtocareaboutit.
AlarmPrototype
Description
“Addentryfailed,eventlist[%s]hastoomanyitems”
%s:eventlistname.
Alarmoccurred
Analarm29958level6occurredat00:08:5901/01/2001UTC
sentbyUPC(MPU)%MIX%Addentryfailed,eventlist[myEvent]
hastoomanyitems
AlarmDescription
Whenthesystemrestoretherelativesubeventtotheeventlist,
theeventtotalnumberalreadyreachestheupperthreshold.
SupportedDevices
ZT600/T1200
29959
MessageNo.
29959
DefaultSeverity
Level
6
AlarmRecovery
Available
AlarmType
ProcessingErrorAlarm
NMLevel
5
Cause
ThisalarmmayoccurwhenplugginginorpluggingoutNPC.When
pluggingNPC,becauseothereventlistmemberiscongured,the
eventtotalnumberalreadyreachestheupperthreshold.After
plugginginNPC,ittriestorestoreinterfacerelatedsubeventlist.
Nowthemembernumberisfullandthisalarmappears.
Recommended
Operations
Itisaprompt.Thereisnoneedtocareaboutit.
AlarmPrototype
Description
“Addentryfailed,toomanyeventitems”
%s:eventlistname.
Alarmoccurred
Analarm29959level6occurredat00:08:5901/01/2001UTCsent
byUPC(MPU)%MIX%Addentryfailed,toomanyeventitems
AlarmDescription
Whenthesystemrestoretherelativesubeventtotheeventlist,
theeventtotalnumberalreadyreachestheupperthreshold.
SupportedDevices
G-series,ZXR106900/8900.
29960
MessageNo.
29960
DefaultSecurity
Level
5
AlarmType
"ProcessingErrorAlarm"
NMLevel
5
124CondentialandProprietaryInformationofZTECORPORATION