ZXR10AlarmHandlingManual
Recommended
Operations
Theremayberedundantconguration.PleasecontactZTEforthe
solution.
OAMAlarm
16899
MessageNo.
16899
DefaultSeverity
Level
5
AlarmRecovery
Available
AlarmType
QoSAlarm
NMLevel
4
Cause
CPUload,namelyCPUutilizationratioreachesthesetlowthresh-
old.
Inuence
Itmaybringtotheslowoperationresponse.
RelatedAlarms
16900,16901
Recommended
Operations
Iftheoperationwithgreatconsumptiononcpuiscarriedout
inshorttime,thenitisnormalphenomenon.Commandsshow
process,showprocessdetailcanbeusedtoviewCPUutilization.
AlarmPrototype
Description
%s(M)panel%dcurrentCPUloadis:%d%
%s(S)panel%dcurrentCPUloadis:%d%
Therst%sistheCPUtype.Therst%dispanelnumberand
thesecond%disCPUutilization.
Alarmoccured:
Analarm16899level5occurredat00:52:0701/01/2001UTCsent
byUPC(MPU)1%OAM%CPUloadexceedsthelowestthreshold
NP(M)panel7currentCPUloadis:80%.
Alarmcleared:
Analarm16899level5clearedat00:53:0701/01/2001UTCsent
byUPC(MPU)1%OAM%CPUloadexceedsthelowestthreshold
NP(M)panel7currentCPUloadis:50%.
AlarmDescription
CPUload,namelyCPUutilizationratioexceedsthesetlowthresh-
old.
SupportedDevices
All.
Appendix
Specication
Theplatform4.6.03bandtheupgradeversionssupportthisalarm.
NotCE&PTNversion.
16900
MessageNo.
16900
DefaultSeverity
Level
5
44CondentialandProprietaryInformationofZTECORPORATION