ZXR10AlarmHandlingManual
Correntalarm(Botholdandnewrackscangeneratethisalarm)
isasfollows:
i.Fanrecover:CurrentCabinet/TrunkFanworknormal
14:58:3808/14/2008UTCalarm80clearedFanrecorver:
CurrentCabinet/TrunkFanworknormalsentbyUPC(MPU)
1
AlarmDescription
Fanmalfunction.
SupportedDevices
T128/T64,T600/T1200
Appendix
Specication
T64,T128adoptsoldrack;T600,T1200adoptsnewrack.
BoardAlarms
279
MessageNo.
279
DefaultSeverity
Level
3
Cause
Thelineboardisofine.
Recommended
Operations
Checkwhetherthelineboardisunpluggednormally,ortheboard
ofineiscausedbyabnormallinecard.
293
MessageNo.
293
DefaultSeverity
Level
3
Cause
Whentheactiveboardandstandbyboardchangeover ,theCard
TypereportedbythelowerlayerBSPisnotinthevalidrange.Its
valueisabnormity.
Recommended
Operations
Thisalarmisusedforthelocationofthemalfuction.Ithasno
inuenceontheoperationortheutility.
299
MessageNo.
299
DefaultSeverity
Level
3
AlarmRecovery
Available
AlarmType
EquipmentAlarm
NMLevel
2
Cause
Alarmoccurs:
Deviceisremovedfrom59stacksystem.
22CondentialandProprietaryInformationofZTECORPORATION