Chapter2AlarmMessage
Alarmclears:
Deviceisaddedto59stacksystem.
RelatedAlarms
512,18720,18721.
Recommended
Operations
Checkwhetheranydeviceisremovedfromstacksystem.
AlarmPrototype
Description
Alarmoccurred
RemoveDeviceNo.%d!(%disdevicenumber)
Alarmcleared
AddDeviceNo.%d!(%disdevicenumber)
Example:
15:50:4901/22/2008UTCalarm299cleared%Board%AddDe-
viceNo.3!sentbyStackMasterDevId2
15:52:1301/22/2008UTCalarm299occurred%Board%Remove
DeviceNo.3!sentbyStackMasterDevId2
AlarmDescription
Deviceisremovedfromstacksystem.
SupportedDevices
59stacksystem.
Appendix
Specication
N.A.
300
MessageNo.
300
DefaultSeverity
Level
2
AlarmRecovery
Available
AlarmType
EquipmentAlarm
NMLevel
1
Cause
ThedoubleSFC(MPU,RPU)arebothactiveorbothstandby
causedbyhardwaremalfunction.
Inuence
Therackcannotworknormally.
RelatedAlarms
No.
Recommended
Operations
1.Rebootthetwoboardswithabnormalalarm.
2.Ifrebootoperationisinvalid,contactwithZTEservicestaff.
3.ZTEservicestaffcaninputprintHardwareStateinrosand
recordtheresult.
AlarmPrototype
Description
2%sis%s,systemabnormal.
Therst%sistheabnormalCPUtype.GenerallyitisSFC,MPU
orRPU.Thesecond%sistheabnormalmasterorslavestate.
Thesecond%sistheabnormalmasterorslavestate.
16:30:3806/21/2007UTCalarm300occurred2SFCismas-
ter ,systemabnormal.sentbyUPC(MPU)2
16:38:3906/21/2007UTCalarm300cleared2SFCismaster ,sys-
temabnormal.sentbyUPC(MPU)2
AlarmDescription
ThedoubleSFC(MPU,RPU)arebothactiveorbothstandbycaused
byhardwaremalfunction.
CondentialandProprietaryInformationofZTECORPORATION23