Chapter4TRAPMessages
TheportPoEpowersupplystatustype:
disabled1
searching2
deliveringPower3
fault4
test5
otherFault6
pethMainPowerUsageOnNotification
Message
Description
PSEtotalpowerofthepowersupplyexceedspowerthreshold.
TriggerConditions
1.PSEtotalpowerofthepowersupplyexceedspowerthreshold.
2.ThecongurationofSNMPrelatedtoPoEsendingtrapiscor-
rect.
Recommended
Operations
N.A.
BoundVariables
pethMainPseGroupIndexPSEdevicenumber
OID1.3.6.1.2.1.105.1.3.1.1.1
pethMainPseConsumptionPowerPSEtotalpowerofpowersupply
OID1.3.6.1.2.1.105.1.3.1.1.4
pethMainPseUsageThresholdPSEpowerthreshold
OID1.3.6.1.2.1.105.1.3.1.1.5
pethMainPowerUsageOffNotification
Message
Description
PSEtotalpowerofthepowersupplyrecoversintherangeofpower
threshold.
TriggerConditions
1.PSEtotalpowerofthepowersupplyexceedspowerthreshold
orrecoversintherangeofpowerthreshold.
2.ThecongurationofSNMPrelatedtoPoEsendingtrapiscor-
rect.
Recommended
Operations
N.A.
BoundVariables
pethMainPseGroupIndexPSEdevicenumber
OID1.3.6.1.2.1.105.1.3.1.1.1
pethMainPseConsumptionPowerPSEtotalpowerofpowersupply
OID1.3.6.1.2.1.105.1.3.1.1.4
pethMainPseUsageThresholdPSEpowerthreshold
OID1.3.6.1.2.1.105.1.3.1.1.5
CondentialandProprietaryInformationofZTECORPORATION275