ZXR10AlarmHandlingManual
board;thethird%distheFahrenheittemperatureofboard;the
fourth%disthecentigradetemperatureofthesetthresholdand
thefth%distheFahrenheittemperatureofthesetthreshold.
AlarmOccurred
%sCurrentlocaltemperatureis%d/%dF ,underthelowthresh-
old(%d/%dF)
AlarmCleared
%sCurrentlocaltemperatureis%d/%dF ,exceedsthelow
threshold(%d/%dF)
Therst%sistheboardtypeandisxedtoBICboard.Thereis
nopanelnumberonBICboard,sothedisplayformatisdifferent
fromotherboard:therst%disthecentigradetemperatureof
theboard,thesecond%distheFahrenheittemperatureofboard,
thethird%disthecentigradetemperatureofthesetthresholdand
thefourth%distheFahrenheittemperatureofthesetthreshold.
Analarm63level5occurredat01:58:0001/28/2001UTCsent
byUPC(MPU)2%ENVIRONMENT%SFCPanel1Currentlocaltem-
peratureis33/91F ,underthelowthreshold(40/104F)
Analarm63level5clearedat01:58:2001/28/2001UTCsentby
UPC(MPU)2%ENVIRONMENT%SFCPanel1Currentlocaltem-
peratureis33/91F ,exceedsthelowthreshold(-10/13F)
AlarmDescription
Boardtemperatureislowerthanthesetlowerthreshold
SupportedDevices
T128/T64,T600/T1200
Appendix
Specication
N.A.
64
MessageNo.
64
DefaultSeverity
Level
5
AlarmRecovery
Available
AlarmType
EnvironmentalAlarm
NMLevel
4
Cause
Boardtemperatureishigherthanthesetrst-hightemperature
threshold.
Thecommandusedtosetthresholdforequipmenttemperatureis:
temper-thresholdUPCmasterlocallowthreshold-20rst-high-
threshold55second-highthreshold90
RelatedAlarms
63,65
Recommended
Operations
Decreaseboardtemperatureifnecessary.Decreasetheenviron-
menttemperatureoftheequipmentbythefanheatdissipation.
AlarmPrototype
Description
AlarmOccurred
%sPanel%dCurrentlocaltemperatureis%d/%dF ,exceedsthe
rsthighthreshold(%d/%dF)
AlarmCleared
10CondentialandProprietaryInformationofZTECORPORATION