PAGE 1 OF 4
ZURN INDUSTRIES, LLC 5900 Elwin Buchanan Drive, Sanford, NC U.S.A. 27330, Ph. 1-800-997-3876, Fax 919-775-3541
In Canada: ZURN INDUSTRIES LIMITED 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, Ph. 905-405-8272, Fax 905-405-1292
Rev. C Date: 6/25/2018 C.N. No. SAN008311 Prod. | Dwg. No. CF1193
AQUASPEC FAUCETS
MODEL - Z86500-XL SERIES
CENTERSET METERING
TECHNICAL INFORMATION
®
1. THE WATER SUPPLY LINE MUST BE THOROUGHLY FLUSHED BEFORE FAUCET INSTALLATION.
2. REMOVE FAUCET BODY FROM CARTON AND PLACE FAUCET ON SINK.
3. ATTACH MOUNTING NUTS (#7) ONTO SHANKS FROM UNDER SINK.
4. HAND TIGHTEN MOUNTING NUTS (#7). DO NOT OVER TIGHTEN, YOU COULD DAMAGE THE FIXTURE.
5. ATTACH LAVATORY SUPPLY TO THE OUTLET OF THE SUPPLY STOP AND CONNECT TO FAUCET WITH RISER NUT
(#8).
6. REMOVE MAINTENANCE TAG FROM SPOUT END AND ATTACH TO SHANK OF FAUCET UNDER SINK FOR FUTURE
REFERENCE.
7. OPTIONAL - POP-UP (-P)/ GRID STRAINER (-G)/HANDICAP OFFSET GRID DRAIN (-GH):
INSTALL POP-UP OR GRID STRAINER IN SINK OUTLET AND PLUMB WASTE CONNECTION.
8. INSTALL SPRAY OUTLET (#6) INTO FAUCET AND HAND TIGHTEN.
9. TURN WATER SUPPLY ON AND OPERATE THE FAUCET WHILE CHECKING FOR LEAKS.
10. METERING CARTRIDGE IS FACTORY PRESET FOR A 10 TO 15 SECOND CYCLE AT 80 PSI, IF ADJUSTMENT IS
NECESSARY, SEE “ADJUSTING THE CYCLE TIME” SECTION (PAGE 2).
IMPORTANT THE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT
FOREIGN MATTER AND DEBRIS FROM CLOGGING AND/OR DAMAGING INTERNAL COMPONENTS
IMPORTANT THE FAUCET HAS AN INTEGRAL SHANK FILTER ASSEMBLY INSTALLED IN THE BODY UNDER THE
METERING CARTRIDGE TO PREVENT FOREIGN MATTER AND DEBRIS FROM DAMAGING THE FAUCET. THE INTEGRAL
FILTER MAY BE REMOVED TO BE BACK-FLUSHED AND CLEANED IF INSUFFICIENT FLOW IS DETECTED. THE INTE-
GRAL SHANK FILTER ASSEMBLY MUST BE RE-INSTALLED AFTER SERVICING TO ENSURE PROPER FUNCTIONING OF
THE METERING CARTRIDGE.
*
*
FLOW: 0.25 GPC MAXIMUM; PRESET AT FACTORY TO 10 TO 15 SECONDS @ 80 PSI ADJUSTABLE
MAXIMUM PRESSURE: 80 PSI
MAXIMUM TEMPERATURE: 140
O
F
*
INSTALLATION INSTRUCTIONS
FILTER REPLACEMENT
1) Remove handle and cartridge
2) Remove filter with
1
4
" Allen wrench
3) Replace or clean filter, re-install filter
4) Install cartridge and handle
(SEE OTHER SIDE FOR ADDITIONAL
INSTRUCTIONS)
INSTRUCTION GUIDELINES
1) Flush supply lines thoroughly before installing faucet.
2) Install 1.0 or 0.5 GPM spray outlet only, hand tighten.
3) See under handle for run time adjustment.
Need Help? 1-800-997-3876 or visit
www.zurn.com
(SEE OTHER SIDE FOR ADDITIONAL INSTRUCTIONS)
FILTER
(G68020)
SHANK
Remove this tag and place on supply line Remove this tag and place on supply line
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov
Question and Answer IconNeed help?

Do you have a question about the ZURN AQUASPEC Z86500-XL-P Series and is the answer not in the manual?

ZURN AQUASPEC Z86500-XL-P Series Specifications

General IconGeneral
Product TypeFlush Valve
SeriesZ86500-XL-P
ADA CompliantYes
Inlet Connection1 inch NPT
Rough Bronze Valve BodyYes
Outlet Connection2 inch NPT
Adjustable High Temperature Limit StopYes
Body MaterialBronze
FinishChrome
Flush Volume1.6 gpf

Summary

Technical Information

Flow Rate and Pressure Specifications

Technical specifications for flow rate, preset cycle time, and maximum pressure.

Water Supply Line Flushing

Instruction to thoroughly flush water supply lines before faucet installation.

Integral Shank Filter

Details on the faucet's integral shank filter and its maintenance requirements.

Health and Safety Warning

Warning regarding cancer and reproductive harm as per P65.

Installation Instructions

Step-by-Step Installation Process

Detailed steps for installing the faucet, including connecting supply lines and mounting.

Maintenance

Cleaning and Finish Care

Guidelines for cleaning the faucet's chrome-plated finish using mild cleaners.

Metering Cartridge Removal and Replacement

Procedure for removing, inspecting, and replacing the metering cartridge.

Integral Shank Filter and Aerator Maintenance

Instructions for cleaning or replacing the integral shank filter and aerator.

Adjusting the Cycle Time on Zurn Metering Faucet

Cycle Time Adjustment Procedure

Steps to adjust the faucet's cycle time using the adjustment nut.

Metering Faucet Troubleshooting Guide

No Water Dispensing Issues

Troubleshooting steps for when no water is dispensed from the faucet.

Faucet Shuts Off Too Quickly

Solutions for issues where the faucet shuts off prematurely.

Faucet Runs Too Long or Won't Shut Off

Troubleshooting for faucets that remain on or do not shut off properly.

Related product manuals