35
Parameter Parameter Name Range Default Note
911
Count of rings
before incoming
call answering
1-99 2
Warning!!! No connection is
established if a higher value is
entered than is allowed by the
PBX ringing timeout!!!
912
Max. call duration 1-99 12=120s Range of 10s-990s
913
Log-in timeout 1-99 3 3 = 30 seconds
915
Hang-up time
between calls
5-99 15 = 1.5s
921
Code lock mode 0-1 1 = enabled
922
Buttons replaced
by keypad
0-1 0 = disabled
923
Telephone mode 0-1 0 = disabled
924
Tone dialling
during call
0-1 0 = disabled
0 = disabled
1 = enabled
For details on these functions
see the Keypad Description.
931
Microphone
power-up level
0-3 2
0 = Maximum microphone
sensitivity
932
Automatic
response speed
0-3 2
3 = Maximum response speed
933
Reception volume 0-15 7
15 = Maximum reception volume
934
Transmission
volume
0-15 7
15 = Maximum transmission volume
935
Message volume 0-15 7
15 = Maximum message volume
936
Beeping volume 0-12 12
12 = Maximum tone volume
937
DTMF hearing
(side tone) volume
0-3 3
3 = Maximum DTMF volume
938
Loudspeaker
volume
0-15 7
15 = Maximum loudspeaker volume
941
Minimum conti-
nuous tone time
10 - 99 20 = 2s
If the tone is longer,
EntryCom hangs up.
942
Minimum busy tone
period
0-255 8 = 0.08s
943
Maximum busy tone
period
0-255 70 = 0.7s
944
Maximum tone-
space difference
0-255 10 = 0.1s
945
Minimum count of
busy tone periods
2-9 4
These parameters control the
busy tone detection. They are
used for call termination and
automatic dialling.
951
Minimum ringing
tone time
1 - 200 50 = 0,5 s
2
)
952
Minimum long
space time
5 - 100 10 = 1 s
953
Maximum long
space time
10 - 100 60 = 6 s
The longest ringing period
space must be in the interval
between parameters 952 and
953.
Count of ringing
periods
1 - 99 10
If the preset count of periods is
exceeded, the call is terminated
.
954
If the preset count of periods is exceeded and automatic dialling is enabled, another attempt
follows. In the event of Automatic Dialling without Confirmation
, the ringing tone is recognised
and ends before the preset count of periods is exhausted; the call is regarded as successful.
961
Maximum timeout for
pressing the next digit
1-9 5 s During password entering, etc.