Connecting a Redundant Power Supply 33
Figure 13 Fitting a rear rail bracket for rack-mounting
4 Insert the Switch into the 19-inch rack and secure with suitable screws
(not provided). Ensure that ventilation holes are not obstructed.
5 Connect network cabling.
6 Finally, place a unit information label on the unit in an easily accessible
position. The unit information label shows the following:
3Com product name of the Switch
3Com 3C number of the Switch
Unique MAC address (Ethernet address) of the Switch.
Serial number of the Switch
You may need this information if you contact 3Com Technical Support.
Connecting a
Redundant Power
Supply
The Switch 5500 Family has a -48V DC Redundant Power Supply socket.
WARNING: The installation of the Redundant Power Supply (RPS) should
only be carried out by properly trained and qualified personnel.
WARNING: These instructions must be read in conjunction with the RPS
flyer and the safety and installation instructions supplied with your RPS.